Remote Port Specific and Communications Protocol SIS Commands
Symbol definitions for Remote port specific SIS commands
X5)=Password
Up to 12 alphanumeric characters
NOTE:The HTML language reserves certain characters for specific functions (see Special
Characters on page 20).
X5! = Port number
01 = Remote (RS-232) port
02 — 05 = UARTs 1 — 5 (DTP input and output ports)
X5@ = Baud rate
X5#=Parity
X5$ = Data bits
X5% = Stop bits
9600 (default), 19200, 38400, 115200
odd, even, none, mark, space (only the first letter required) (n = default)
7, 8 (default)
1 (default), 2
NOTE: X5! through X5% and X5* are variables for the rear panel Remote RS-232 port. These variables are repeated on page 8 as X3*
through X4# for the RS-232 inserts.
X5^ = Port type
X5& = Verbose mode
0 = RS-232 (default)
1 = RS-422 (not available on DTP CrsossPoint)
0 = Clear or none (default for Telnet connection)
1 = Verbose mode (default for RS-232 or USB connection)
2 = Tagged responses for queries
3 = Verbose mode and tagged for queries
NOTE: If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command
does (for example, the read matrix name command ECN}, returns Ipn•X2)]).
X5* = Port timeout interval (in 10-second increments)
1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
SIS Command and Response Table for Remote and Communications Protocol Commands
Command Function
SIS Command
Response
(Host to Unit)
(Unit to Host)
Additional description
Read serial port parameters
EX5)CA}
Ipa•X5)]
ECA}
X5)]
E•CA}
Ipa•]
EX5)CU}
Ipu•X5)]
ECU}
X5)]
E•CU}
Ipu•]
EX5!*X5@,X5#,X5$,X5%CP}
CpnX5!•CcpX5@,X5#,X5$,X5%]
EX5!CP}
X5@,X5#,X5$,X5%]
Configure flow control
Read flow control
Configure receive timeout
EX5!*Y8^,Y8&CF}
EX5!CF}
EX5!*Y8*,Y8(CE}
Set administrator password
Read administrator password
Reset (clear) administrator password
Set user password
Read user password
Reset (clear) user password
Set serial port parameters
CpnX5!•CflY8^,Y8&]
Y8^,Y8&]
CpnX5!•CceY8*,Y8(,Y9),Y9!]
NOTE: The configure command is sufficient as shown for most users, with the priority (Y9)) and length or delimiter (Y9!) omitted).
The response in this case is “CpnX5!•CceY8*,Y8(,0,00000L],” with the default Y9) and Y9! values returned.
Read receive timeout
Set mode
Read mode
Set verbose mode
Read verbose mode
Configure current port timeout
Read current port timeout
Configure global IP port timeout
Read global IP port timeout
EX5!CE}
EX5!*X5^CY}
EX5!CY}
EX5&CV}
ECV}
E0*X5*TC}
E0TC}
E1*X5*TC}
E1TC}
Y8*,Y8(,Y9),Y9!]
CpnX5!•CtyX5^]
X5^]
VrbX5&]
X5&]
Pti0*X5*]
X5*]
Pti1*X5*]
X5*]
DTP Crosspoint 84 IPCP Series Matrix Switchers • Programming Guide