Download Enterasys (TPXMIM-34) Networking Hub
Transcript
CHAPTER 2: SPECIFICATIONS/REQUIREMENTS Minimum Packet Repeated: 96 bits including preamble (the TPXMIM extends packet fragments using the JAM [1,0] data pattern). FAULT Protection: Each segment disconnects itself from the other segments following 31 consecutive collisions, or if the collision detector of a segment remains ON longer than 110 µs. The TPXMIM automatically reconnects the problem segment after it transmits or receives one packet without a collision. Environmental Requirements Operating Temperature: +5 to +40C (41° to 104°F) Non-Operating Temperature: -30 to +80C (-22° to 176°F) Operating Humidity: 5 to 95% (non-condensing) Safety This unit meets safety requirements of UL 1950, CSA C22.2 No. 950, and EN 60950; the EMI requirements of FCC Class A and EN 55022 Class A; and the EMC requirements of EN 50082-1. Warning: It is the responsibility of the person who sells the system of which the TPXMIM will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions. Physical Dimensions: 34.04 D x 29.21 H x 5.08 W cm (13.4 D x 11.5 H X 2.0 W inches) Weight: ~ 2 lbs. Page 10 TPXMIM Installation Guide