Page 29
Digital Display Wall Clock Guide
DDC2 / 4-RS Wiring
Synchronous Wired
H
M
BLU / WHT
BRN / WHT
BLK
BLK
115VAC
From
Master Clock
Run
AC Return
Correction
Clock will correct minutes hourly at HH:58 and
hour and minutes twice daily beginning at 5:05.
To
Other Clocks
Set switches 1-5 of S1 as shown.
Indicates depressed side of switch
For 24VAC correction, use wiring
shown on page 23
Wiring applies to secondary wall clocks such as:
Cincinnati D8
Faraday
Honeywell ST402A
1
2
3
4
5
OPEN
6
7
8