DT595A USER MANUAL(EN)
2-Wire Video Intercom System
 Read this manual carefully before using the product, and keep it well for future use.
Parts and Function
The door station is an audio door station without camera,which is designed for DT 2-wire system.
The front panel is made of zinc alloy for better protection against vandalism & cauterization, and
the call button is also made of zinc alloy with blue backlight for auxiliary illumination, the unlock
and talking LED indicator guarantee the door station working efficiently.
With the rainy cover, the door station can be strongly protection against water.
1
Speaker
2
Unlock Indicator
3
Talk Indicator
4
Front Panel
4
5
Call Button
5
6
Microphone
6
7
Rainy Cover
1
2
7
3
Terminal Description
Connection line
SPK adjust
DIP
ON
PROG
1 2 3
CALL button
1 2 3
4P
terminal
1 2 3
Lock Control
Jumper
ON
1 2 3
BUS(Blue&Green)
S2+(Red)
PL(White)
S1+(Yellow)
S1-(Black)
◆ Lock Control Jumper: to select the lock type. Please refer to Electric Lock Connection
◆ DIP switch: to set ID code for door station, total 4 door stations can be supported. Please
refer to DIP Switch Setting.
◆ SPK adjust: to adjust the talk volume.
◆ PROG button: reserve.
◆ CALL button: press to call the user.
◆ 4P terminal: to update software via specified programmer.
◆ Connection line: to connect the bus line and the electronic locks.
BUS(Blue&Green): connect to the bus line, no polarity.
S2+(Red): the S2+ connect with S1- to activate the relay of ERL to extend a camera of DT-CAM,
-3-
please refer to DT-CAM user instructions in details.
PL(White): external lock power input, connect to the power positive(power +).
S1+(Yellow): lock power(+) output.
S1-(Black): lock power(-) output.
Unit Mounting
The location of outdoor station should keep away from snow,rain,and intensity light.
Accessory contents:
Accessories include a screwdriver T20, one M4X10 screw, two PA4X25 screws,three PA3x25
screws,three PM3x12 screws,and five screw stoppers Φ6X30.
Installation steps:
Installation height for door station usually is 145~160cm.
1. Use screws to fix the back panel and rainy cover to the wall after connect the cable correctly.
2. Attach the front panel to the back panel, then use the screw to fix it.
1
2
3
PM3*12
M4*10
Wiring and Connection
Basic one-to-one connection
AC~
PC6
Monitor
Bus PL S2+ S1+ S1-
+
BUS(Blue&Green); S2+(Red); PL(White); S1+(Yellow); S1-(Black);
-4-
Multi Door Station Connection
4# Camera
3# Camera
ID=11
2# Camera
1# Camera
ID=10
ID=01
ID=00
ON
ON
ON
ON
12 3
12 3
12 3
12 3
Monitors
Bus PL S2+ S1+ S1-
Bus PL S2+ S1+ S1-
Bus PL S2+ S1+ S1-
Bus PL S2+ S1+ S1-
AC~
DIP=on,off,off
A B C D
DBC-4S
PC6
OFF
ON
Impedance
Switch
BUS(Blue&Green); S2+(Red); PL(White); S1+(Yellow); S1-(Black);
Multi Monitors Connection
Basic IN-OUT wiring mode
ON
ON
ON
ON
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
Code=0, DIP-6=off
Code=1, DIP-6=off
monitor
monitor
monitor
AC~
PC6
ID=00
ON
12 3
-5-
Code=14, DIP-6=off
Code=15, DIP-6=on
monitor
With DBC-4S Wiring Mode
ON
monitor
monitor
1 2 3 4 5 6
Impedance
switch
Code=14, DIP-6=on
A B C D
Code=15, DIP-6=on
ON
1 2 3 4 5 6
Code=12, DIP-6=on
Code=13, DIP-6=on
ON
1 2 3 4 5 6
DIP=on,off,off
monitor
ON
monitor
Code=2, DIP-6=on
Impedance
switch
A B C D
Code=3, DIP-6=on
monitor
1 2 3 4 5 6
1 2 3 4 5 6
Code=1, DIP-6=on
DIP=on,off,off
ON
ON
monitor
OFF ON
DBC-4S
1 2 3 4 5 6
ON
monitor
OFF ON
DBC-4S
ON
1 2 3 4 5 6
monitor
1 2 3 4 5 6
Code=0, DIP-6=on
AC~
PC6
ID=00
ON
12 3
-6-
With DT-CAM wiring mode
The audio door station DT595A can be extended an additional CCTV camera to be a video door
station. For more details about the camera, please refer to DT-CAM user instructions.
DT-CAM
AC~
ERL
OUT
IN
PC6
DS
DT595A
Monitor
IM
Bus PL S2+ S1+ S1-
Electric Lock Connection
Door Lock Controlled with Internal Power
1 2 3
Connect one lock
Note:
1. Electronic lock of Power-on-to-unlock type
should be used.
2. The door lock is limited to 12V, and holding
current must be less than 250mA.
3. The door lock control is not timed from Exit
Button(EB).
4. The Unlock Mode Parameter of Monitor must
be set to 0 (by default).
Jumper position in 2-3
Bus
PL S2+ S1+ S1-
*EB
LOCK
Door Lock Controlled with Dry Contact
Take off the Jumper
Bus
PL S2+ S1+ S1-
POWER
SUPPLY
LOCK
-7-
Note:
1. The external power supply must be used
according to the lock.
2. The jumper must be taken off before connecting.
3. Setup the Unlock Mode of Monitor for different
lock types.
* Power-on-to-unlock type:Unlock Mode=0 (by default)
* Power-off-to-unlock type:Unlock Mode=1
DIP Switch Setting
The DIP switch is designed to set the code for door station and monitor, there are two states for
each DIP switch, please refer to the following sketch map.
ON(1)
ON
OFF(0)
ON
=
=
Door station DIP setting
Total 3 bits can be configured, bit-1 and bit-2 are used to assign ID code for door station, bit-3 is
used to match the video impedance.The switches can be modified either before or after installation.
Bit state
Description
ON
1 23
ID = 0(00), set to the first door station
ON
1 23
ID = 1(10), set to the second door station
ON
1 23
ID = 2(01), set to the third door station
ON
1 23
ID = 3(11), set to the fourth door station
Note: if the video impedance need to match, please set the bit-3 on.
Indoor monitor DIP setting
There are 6 bits in total. The DIP switches are used to configure the user code for Monitors.
Bit-6 is an video impedance match switch, which have to be set to ON if match the impedance,
otherwise set to OFF.
Bit-1~Bit-5 are used to set user code, to DT595A door station, the user code should set to 0~15.
Please refer to the following settings:
-8-
Bit state
ON
1 2 3 4 5 6
User code
code=0
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
ON
1 2 3 4 5 6
User code
code=6
ON
ON
1 2 3 4 5 6
Bit state
code=1
code=2
code=3
code=4
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
Bit state
ON
1 2 3 4 5 6
User code
code=11
ON
code=7
code=8
code=9
code=10
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
code=12
code=13
code=14
code=15
code=5
1 2 3 4 5 6
Specification
•
•
•
•
•
•
Power Supply:DC 24V
Power Consumption:Standby 60mA; Working status 200mA
Lock Power Supply:12Vdc, 300mA(Internal Power)
Working Temperature: -10ºC ~ +45ºC
Wiring: 2 wires,non-polarity
Dimension:137(H)x49(W)x28(D)mm
Precaustions
• Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent.
If necessary, please use a little pure water or dilute soap water to clean the dust.
• The unit is weather resistant. However do not spray high pressure water on access control keypad
directly. Excessive moisture may cause problems with the unit.
• You must use the right adaptor which is supplied by the manufacture or approved by the manufacture.
• Pay attention to the high voltage inside the products, please refer service only to a trained and qualified
professional.
-9-
Cable Requirements
The maximum distance of the wiring is limited in the DT system. Using different cables may also
affect the maximum distance which the system can reach.
The farest monitor
monitor
with two or four monitors
monitor
monitor
DBC-4S
B
C
AC~
PC6
When Monitor quantity < 20
Cable Usage
A
B
C
Twisted cable 2x0.75 mm2 60
60
30
80
80
40
A
B
C
70
30
20
70
50
30
Twisted cable 2x1 mm2
A
When Monitor quantity >20
Cable Usage
Twisted cable 2x1 mm2
Twisted cable 2x1.5 mm
2
Note:If the monitor has been specified
the distance,refer to the parameter.
-10-
The design and specifications can be changed without notice to the user. Right to
interpret and copyright of this manual are preserved.
DT-ENG-595A-V1 P120924
. Right to interpret and copyright of this manual are preserved.
Printed 2012. 09
DT-DJ4S
Audio Phone
User Manual
8888
1
2
 Read this manual carefully before using the product, and keep it well for future use.
1. Parts and Functions
97.1
33.2
7 segment LED
187
150
8888
Handset
2
1
Up button
Menu button
Down button
Cancel button
Unlock 2nd button
Unlock button
Speaker
Handset line
Side View
Key functions
7 segment LED
Display setting informations
Handset
Pick up to communicate with visitor
Hand line
Connect handset with monitor
Unlock button
Press to release the door
Unlock 2nd button Press to release the second door
Up button
Press to move up or increase the value
Down button
Press to move down or decrease the value
Menu button
Press and hold for 2s to open the setting menu shortcuts.
Cancel button
Press to cancel the operations
Speaker
Send out voice from the visitor
2. Operation Instructions
1) Door opening function: When visitor calls from outdoor station, the monitor rings,
pick up handset to talk with the visitor, then press the Unlock button to open the door.
If the system connect 2 locks,press Unlock 2nd button to open the second door.
2) Monitoring & calling menu: Pick up handset in standby mode,the LED will be
shown a scroll information “Intr Call”,pressing Up button or Down button can stop the
scroll. To quit this menu, please tap Cancel button.
3) Entrance monitoring: In monitoring & calling menu page, the LED show "dsx"(x=1~4,refer to part 3-Numbers of door station),it means that the monitor select "x"
door station to monitor. Press Up / Down button to increase/decrease the value,then
press Menu button to activate the monitoring.
4) Inner call: In monitoring & calling menu page, use Up / Down button to select
"-ALL" item on LED,then press Menu button to activate the inner call,all monitors
connected to the system will ring at the same time. Pick up any monitor,the others will
stop ringing immediately.(note that the user code must be the same for all monitors to
activate the inner call function)
5) Intercom call: In monitoring & calling menu page, use Up / Down button to select
"C-xx" (xx=00~31,refer to part3-Numbers of indoor monitor)item on LED,then press
Up / Down button to increase/decrease the value,and press Menu button to confirm the
intercom calling.(note that the user code must be different for all monitors to activate
the intercom call function)
3. Setup Instructions
Press Menu button and hold for 2s in standby mode,the LED will be shown a scroll
information "User Set-",press Up button or Down button to stop the scroll,and the LED
show the setting items. Press Menu button to select next setting items. To quit this setting menu, please tap Cancel button.
Setting
Item
Door station
call tone
Intercom
call tone
LED
state
Description
Default
1-xx
Set the ring tone calling from outdoor station. Total
12 pieces ring tones can be selected(xx=01~12),press
Up button or Down button to increase/decrease the
value,settings will be performed immediately.
02
2-xx
Set the ring tone calling from intercom call or
inner call. Total 12 pieces ring tones can be
selected(xx=01~12), press Up / Down button to increase/decrease the value, settings will be performed
immediately.
12
Setting
Item
LED
state
Description
Default
Door bell call tone
3-xx
Set the ring tone calling from door bell. Total 12
pieces ring tones can be selected(xx=01~12),press
Up button or Down button to increase/decrease
the value,settings will be performed immediately.
02
Ring volume
4-rx
Set the ring volume for call tone,range from 0~9.
6
5-0x
Maximum 4 door stations can be selected,this
item is used to set the numbers of door station
that can be surveilled by indoor monitor. Refer to
part 2 ->Entrance Monitoring.
1
Numbers of
indoor monitor
6-xx
Maximum 32 indoor monitors can be selected,this
item is used to set the numbers of indoor monitor
that can be selected to intercom. Refer to part 2
->Intercom call.
04
Slave address
setting for monitor
7-dx
Rang from 0~3,"0"-master monitor,"1~3"-slave
monitor.
0
8-FS
The restore to default function allows the user to
recover the settings to factory setting. Select "8FS" item on LED,then press Up button,"yES"will be asked,press Up button again,the LED
will be shown"SUCC",that means settings are
restored to default.
-
Numbers of door
station
Restore to default
setting
4. Specification
●●
●●
●●
●●
●●
Power Supply:
Power Consumption:
7 segment LED:
Wiring: Dimension: DC24V
standby 25mA,working 110mA
4 digits dynamic
2 wires, non-polarity
187(H)X97(W)X33(D)mm
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.