Download CONTROLLER MANUAL SPINCHILLER C.D.A - mark-off
Transcript
SUMMARY CLIVET TALK LOCAL INTERFACE................................................................................................................. 3 DESCRIPTION OF THE BUTTONS ................................................................................................................................4 DESCRIPTION OF THE MAIN SCREEN.........................................................................................................................5 SYSTEM COMPOSITION.................................................................................................................................. 6 CENTRAL MODULE CLIVETTALK.LOCAL.M1...............................................................................................................6 DESCRIPTION OF THE JUMPERS.............................................................................................................................7 I/O CLIVETTALK.LOCAL.M1 .......................................................................................................................................7 EVAPORATOR MODULE CLIVETTALK.LOCAL.EX1 .....................................................................................................9 DESCRIPTION OF THE JUMPERS.............................................................................................................................9 I/O CLIVETTALK.LOCAL.EX1....................................................................................................................................10 TANDEM COMPRESSOR MODULE CLIVETTALK.LOCAL.C2 ....................................................................................11 TRIO COMPRESSOR MODULE CLIVETTALK.LOCAL.C3...........................................................................................11 DESCRIPTION OF THE JUMPERS...........................................................................................................................11 CLIVETTALK.LOCAL.C2 AND CLIVETTALK.LOCAL.C3 ..........................................................................................12 INITIALISING THE MODULES ....................................................................................................................... 13 BASIC RULES FOR CONFIGURATION........................................................................................................................13 SETTING THE HARDWARE ADDRESS....................................................................................................................13 SETTING THE SOFTWARE ADDRESS ....................................................................................................................14 SETTING THE HARDWARE ADDRESS OF THE CENTRAL MODULE....................................................................15 SETTING THE HARDWARE ADDRESS OF THE EVAPORATOR MODULE ...........................................................15 SETTING THE HARDWARE ADDRESS OF THE TRIO AND TANDEM MODULES.................................................15 TABLE FOR SETTING THE HARDWARE ADDRESS...............................................................................................16 LOCAL INTERFACE ADDRESS .................................................................................................................... 17 REMOTE INTERFACE ADDRESS ................................................................................................................................17 CONFIGURATION EXAMPLE ........................................................................................................................ 18 SETTING THE HARDWARE ADDRESS .......................................................................................................................18 SETTING THE SOFTWARE ADDRESS........................................................................................................................19 PARAMETER MENU TREE ............................................................................................................................ 20 OPERATING STATUS MENU TREE.............................................................................................................................39 GENERAL UNIT STATUS MENU ..................................................................................................................................40 LIST OF ALARMS ........................................................................................................................................... 42 CENTRAL MODULE ALARMS ......................................................................................................................................42 COMPRESSOR MODULE ALARMS .............................................................................................................................43 EVAPORATOR MODULE ALARMS ..............................................................................................................................44 OPERATION OF THE TEMPERATURE CONTROLLER............................................................................... 45 COOLING ......................................................................................................................................................................45 DETERMINING THE TEMPERATURE DIFFERENCE FOR EACH COMPRESSOR ................................................45 FREECOOLING .........................................................................................................................................................46 HEATING .......................................................................................................................................................................51 DETERMINING THE TEMPERATURE DIFFERENCE FOR EACH COMPRESSOR ................................................51 STEP ACTIVATION – SCAN TIMES .............................................................................................................. 52 STEP DEACTIVATION ..................................................................................................................................................52 COMPENSATION............................................................................................................................................ 52 SET POINT CORRECTION IN COOLING ...................................................................................................... 53 SET POINT CORRECTION IN HEATING ....................................................................................................... 54 SECOND SET POINT FROM DIGITAL INPUT............................................................................................... 55 DEMAND LIMIT ............................................................................................................................................... 56 MAINTENANCE SET POINT .......................................................................................................................... 58 RESOURCE MANAGEMENT ALGORITHM .................................................................................................. 59 BALANCING OF THE CAPACITY DELIVERED ............................................................................................................59 Data creazione 10/09/03 DS03I009GB--00 Pagina 2 di 59