TM 9-2330-384-14&P
4-28. TRIPLE CLEARANCE LIGHT ASSEMBLY REPLACEMENT.
a.
Removal
b.
Equipment Conditions:
Materials/Parts:
R e f Conditions
2-14 Intervehicular electrical cable disconnected from semitrailer.
l
One connector
Corrosion preventive compound (Item 7,
Appendix E)
General Safety Instructions:
Tools:
l
installation
Tool kit, general mechanic’s
Wire terminal kit
l
When performing electrical maintenance,
ALWAYS disconnect intervehicular electrical cable from semitrailer.
a. REMOVAL
WARNING
When performing electrical maintenance, ALWAYS disconnect intervehicular electrical cable from semitrailer. Failure to follow this warning
may create a spark and explosion, resulting in serious injury or death to
personnel.