Download Bacharach Model 200 Specifications
Transcript
MODEL 300 COMBUSTION ANALYZER ACCURACY (68°F [20°C], 45% RELATIVE HUMIDITY) Stack Temperature ........ ±1% full scale Oxygen ............................ ±0.6% O2 Carbon Monoxide ........... ±5% reading or ±10 ppm, whichever is greater NOX (Optional) ............... ±5% reading or ±10 ppm, whichever is greater SO2 (Optional) ................ ±5% reading or ±10 ppm, whichever is greater PROBE TEMPERATURE EXPOSURE LIMITS The time and temperature limits for the probe assembly (24-7131) are listed below. Stack Temperature Probe Exposure Time Limit 100–1000°F (38–538°C) 1000–1200°F (538–649°C) 1200–1400°F (649–760°C) Unlimited 30 mins. per exposure 10 mins. per exposure NOTE: The high-temperature extended-probe options have unlimited exposure times up to 2000°F (1093°C). FUNCTIONS Directly Measures and Displays: • • • • • • Stack Temperature (up to 2000°F [1093°C]) Carbon Monoxide level: (0–3700 ppm over 32–104°F [0– 40°C]) Oxygen level (0.1 to at least 23.5%) Oxygen Sensor output in millivolts NOX level (0-1999 ppm) (NSX units) SO2 level (0-1999 ppm) (NSX units) Instruction 24-9223 v