4. System Features and Examples 4.1 Features Classification Control Function Item Notes/Cautions • Multiple unit operation Maximum 15 units with PZ-60DR-E & PZ-41SLB-E; 16 units with PZ-52SF-E or other M-NET controllers. • Remote controller operation Last condition priority before turning off the unit. • External device operation and external pulse control Signal : 12VDC, 24VDC, uncharged a-contact. • External monitor signal output and supply air fan monitor output Uncharged a-contact (external monitor/supply air fan monitor change). • External control operation mode setting ON/OFF, ON, OFF and external control priority ON/OFF mode. • Timer control Weekly timer & simple timer available for PZ-60DR-E. • Delayed start Delayed time can be varied only when the PZ-41SLB-E is connected. • Automatic recovery following power supply interruption (*1) Automatic power recovery is fixed when PZ-60DR-E or PZ-41SLB-E is connected. • Power supply start/stop function Function cannot be performed when PZ-41SLB-E is connected. • High/low/Extra-Low change input Uncharged a-contact (Remote display adaptor (PAC-SA88HA-E) is required.) • Remote/local control change Uncharged a-contact (Remote ON/OFF adaptor (PAC-SE55RAE) is required.)(Function cannot be performed when using PZ-41SLB-E.) • M-NET air conditioning operation. Only when M-NET transmission cable is connected. • System controller by Mitsubishi building air control management system Only when M-NET transmission cable is connected. • Interlocked with Mr. Slim Function cannot be performed with PZ-41SLB-E. • Lossnay (heat recovery) ventilation/automatic By-pass ventilation switch Also external By-pass switcing is available(Remote display adaptor (PAC-SA88HA-E) is required). • For cold area operation Installation Maintenance • Two non polar wires for remote controller For PZ-60DR-E, PZ-41SLB-E connection: ø 0.65 to 1.2 PVC cable or 0.3 mm2 to 1.25 mm2 strand wire. For M-NET connection: 1.25 mm2 to 2.00 m2 shielded wire or equivalent. • Address setting unnecessary Excluding central controller system (except automatic address). • Test operation switch For Lossnay single unit test operation. • Filter maintenance display (remote controller display) Filter, core maintenance display for PZ-60DR-E. • Inspection display (remote controller, control board LED) Error code indication for PZ-60DR-E. • M-NET power supply display (control board LED) *1 The operation condition is saved, and when the power is turned off and then back on, the operation condition returns to the previous requested condition. (When using PZ-60DR-E, PZ-41SLB-E, the start/stop condition from an external device is not saved.) C-5