Table 14-1
(2 of 3)
Result Codes
Numbers
(1)
Numbers
(2)
22
12
CONNECT 9600/ EC**
Connection at 9600 bps with error control
23
16
CONNECT 12000/ EC**
Connection at 12,000 bps with error control
24
13
CONNECT 14400/ EC**
Connection at 14,400 bps with error control
25
17
CONNECT 16800/ EC**
Connection at 16,800 bps with error control
26
15
CONNECT 7200/ EC**
Connection at 7200 bps with error control
27
5
CONNECT 1200/ EC***
Connection at 1200 bps with error control
28
28
CONNECT 38400****
Connection at 38,400 bps
29
14
CONNECT 19200/ EC**
Connection at 19,200 bps with error control
30
30
CONNECT 57600****
Connection at 57,600 bps
31
31
CONNECT 57600/ EC***
Connection at 57,600 bps
32
32
CONNECT 76800****
Connection at 76,800 bps
33
33
CONNECT 76800/ EC****
Connection at 76,800 bps
34
34
CONNECT 115200****
Connection at 115,200 bps
35
35
CONNECT 115200/ EC***
Connection at 115,200 bps
37
37
CONNECT 21600*
Connection at 21,600 bps
38
38
CONNECT 24000*
Connection at 24,000 bps
39
39
CONNECT 26400*
Connection at 26,400 bps
40
40
CONNECT 28800*
Connection at 28,800 bps
41
41
CONNECT 31200*
Connection at 31,200 bps
Word
Description
* Only appears when the Extended Result Codes configuration option is enabled.
** Only appears when the modulation is V.34 and the Extended Result Codes configuration option is set to Add/EC or
Add/V.42. Receive Rate (RX) and Transmit Rate (TX) appear in place of the single rate.
*** Only appears when the Extended Result Codes configuration option is set for Add/EC. If this configuration option is
set for Add/V42, MNP, then either V42t, V42b, V42, MNP5, MNP4, MNP3, MNP2, or NoEC appears.
**** Only appears when the Extended Result Codes configuration option is set for Use_DTE_Rate. This displays the
DTE data rate instead of the line rate.
14-4
October 1998