Download Rinnai 37AHB SERIES Specifications
Transcript
Rinnai Corporation Hydronic Furnace (37AHB) Manual 35 UNIT SIZE TAP 5 (L) TAP 4 (ML) TAP 2 (MH) TAP 1 (H) ECM SPEED TAP EWT (OF) 160 150 140 160 150 140 160 150 140 1.5 160 150 140 130 120 AHB60 + RC80HPi(e) 2.0 130 120 AHB60 + RC80HPi(e) 2.5 130 120 AHB60 + RC80HPi(e) 3.0 130 120 AHB60 + RC80HPi(e) SUPPORTS COOLING CAP. RANGE (TONS) NET HEATING CAPACITY (MBH) NET HEATING CAPACITY (MBH) NET HEATING CAPACITY (MBH) NET HEATING CAPACITY (MBH) NOMINAL HEATING CAPACITY 0.1 0.2 0.3 0.5 0.6 AIRFLOW (CFM) 0.4 0.7 0.8 0.9 in. W.C. 69.1 62.6 53.8 46.5 40.3 68.0 61.5 52.9 45.7 39.6 66.6 60.3 51.8 44.8 38.8 64.3 58.1 50.0 43.2 37.4 59.6 55.1 46.8 39.7 33.3 844 63.8 58.6 49.6 41.9 35.0 971 66.9 60.5 52.1 44.5 37.9 57.2 52.9 44.9 38.1 32.0 810 61.9 56.9 48.1 40.6 34.0 942 65.7 59.4 51.2 43.7 37.3 51.8 54.9 59.0 53.3 45.9 39.2 33.4 984 57.3 51.9 44.7 38.2 32.5 53.6 49.3 41.7 35.2 29.5 817 51.5 47.3 40.0 33.8 28.3 784 49.3 45.6 38.7 32.8 27.6 698 47.0 43.4 36.9 31.2 26.3 665 44.2 40.9 34.7 29.4 24.7 626 AIRFLOW (CFM) 55.6 51.1 43.2 36.5 30.5 847 AIRFLOW (CFM) 60.9 55.1 47.4 40.5 34.5 41.0 37.9 32.2 27.3 22.9 581 49.3 45.3 38.3 32.4 27.1 751 55.6 50.3 43.4 37.0 31.5 955 61.3 55.4 47.6 41.2 35.7 37.6 34.8 29.6 25.0 21.0 533 47.0 43.2 36.5 30.8 25.8 715 54.6 49.4 42.5 36.3 31.0 937 58.2 52.6 45.2 39.1 33.9 35.6 32.9 28.0 23.7 19.9 504 44.7 41.1 34.7 29.3 24.5 680 52.9 47.8 41.2 35.2 30.0 908 53.8 48.6 41.8 36.2 31.3 32.9 30.4 25.8 21.9 18.4 466 42.2 38.8 32.8 27.7 23.1 642 40.2 36.4 31.3 26.8 22.8 690 46.6 42.2 36.3 31.4 27.2 889 1.0 24 30 TBD 24 6. See Note TBD 30 6. See Note TBD 24 See Note 6. TBD 30 See Note 6. TBD See Note 20 6. TBD See Note 24 6. TBD See Note 30 6. Minimum Legs @ Optimal Legs @ Maximum legs @ 60 CFM/Leg 50 CFM/Leg 40 CFM/Leg TBD 20 See Note 6. Minimum Legs @ Optimal Legs @ Maximum legs @ 60 CFM/Leg 50 CFM/Leg 40 CFM/Leg TBD 20 6. See Note Minimum Legs @ Optimal Legs @ Maximum legs @ 60 CFM/Leg 50 CFM/Leg 40 CFM/Leg 20 Minimum Legs @ Optimal Legs @ Maximum legs @ 60 CFM/Leg 50 CFM/Leg 40 CFM/Leg Number of 3" Diameter Branch Legs applicable to High Velocity Systems Only. Used only if methods other than Table 3 is used to determine duct sizes. 6. Number of 3” diameter legs specified in table above is for rating point only (i.e. at External Static Pressure of 0.5 in. wc. and speed TAP3, TAP1, TAP2 , TAP2 for AHB45, AHB60, AHB75, AHB90 respectively). Final leg count is to be determined by the installing contractor and is to be based on the following formula: NUMBER OF LEGS = TOTAL AVAILABLE CFM (AT THE SPECIFIC ESP) / DESIRED CFM per LEG (40, 50, or 60 CFM) Example: Given the design point for AHB045 of 0.8 ESP, Low fan speed (Tap5). From table 5.0, available CFM is 569 and the desired CFM per leg is 50 CFM. Therefore, Number of Legs = 569/50 = 11.38 rounded down to 11. 47.9 40.7 34.5 29.0 734 57.8 53.1 44.9 37.9 31.7 880 62.5 56.5 48.7 41.6 35.4 50.7 43.1 36.5 30.7 777 59.8 55.0 46.5 39.3 32.8 911 64.3 58.1 50.1 42.8 36.4 62.8 56.8 48.8 42.2 36.6 AIRFLOW (CFM) 65.5 59.2 50.9 44.0 38.1 1148 1128 1103 1072 1045 1012 70.4 63.7 54.8 47.4 41.0 1343 1318 1296 1270 1248 1225 1197 1168 1109 1025 0 External Static Pressure (ESP) TABLE 5.3: AIR DELIVERY AND PERFORMANCE DATA (BOTTOM OR SIDE RETURN w/ FACTORY SUPPLIED FILTER) NOTES: 1. EWT - Entering Water Temperature (F). 2. CFM - Airflow in (Cubic Feet per Minute). 3. Legs - 3 inch diameter flexible ducts to diffusers. 4. 1 MBH = 1000 BTU/H. 5. Shaded box represents rating point; refer to wiring diagram for factory set speed taps. 37AHB06012KA5 + REU-KA2530FFUD(WD)-US