Download Rinnai 37AHB SERIES Specifications
Transcript
UNIT SIZE Rinnai Corporation Hydronic Furnace (37AHB) Manual TAP 4 (L) TAP 3 (ML) TAP 2 (MH) TAP 1 (H) ECM SPEED TAP EWT (OF) 160 150 140 160 150 140 130 160 150 140 2.5 160 150 140 130 120 AHB75 + RC98HPi(e) 3.0 130 120 AHB75 + RC98HPi(e) 3.5 120 AHB75 + RC98HPi(e) 4.0 130 120 AHB75 + RC98HPi(e) SUPPORTS COOLING CAP. RANGE (TONS) NET HEATING CAPACITY (MBH) NET HEATING CAPACITY (MBH) NET HEATING CAPACITY (MBH) NET HEATING CAPACITY (MBH) NOMINAL HEATING CAPACITY 0.1 0.2 0.3 0.5 0.6 AIRFLOW (CFM) 0.4 0.7 0.8 0.9 in. W.C. 1.0 88.0 78.6 67.7 58.8 49.3 86.4 77.1 66.5 57.7 48.4 84.7 75.7 65.2 56.6 47.4 81.5 72.8 62.7 54.5 45.6 80.2 71.6 61.7 53.6 44.9 AIRFLOW (CFM) 83.3 74.3 64.1 55.6 46.6 78.8 70.4 60.7 52.7 44.1 77.4 69.1 59.6 51.7 43.3 75.5 67.5 58.1 50.5 42.3 74.1 66.1 57.0 49.5 41.5 87.4 78.1 68.5 58.2 50.1 85.5 76.3 67.0 56.9 49.0 83.5 74.6 65.4 55.6 47.8 80.1 71.5 62.7 53.3 45.9 78.2 69.9 61.3 52.1 44.8 AIRFLOW (CFM) 81.9 73.2 64.2 54.5 46.9 76.3 68.2 59.8 50.8 43.7 70.6 63.0 55.3 46.9 40.4 72.6 64.8 56.9 48.3 41.6 70.2 62.7 55.0 46.7 40.2 88.9 78.9 69.9 59.0 50.1 86.9 77.2 68.4 57.7 49.0 84.3 74.9 66.3 56.0 47.6 79.6 70.7 62.6 52.9 44.9 82.1 73.7 64.5 53.3 47.4 78.9 70.8 62.0 51.2 45.5 73.9 76.6 71.4 64.1 56.1 46.4 41.2 68.1 61.1 53.5 44.2 39.3 65.8 59.0 51.7 42.7 38.0 979 63.0 56.5 49.5 40.9 36.3 937 74.5 66.1 58.6 49.4 42.0 59.6 53.5 46.8 38.7 34.4 887 71.8 63.7 56.4 47.7 40.5 55.7 50.0 43.8 36.2 32.2 829 70.1 62.2 55.1 46.5 39.5 52.2 46.9 41.0 33.9 30.1 777 67.9 60.3 53.4 45.1 38.3 TBD See Note 28 6. TBD See Note 35 6. 28 35 TBD See Note 28 6. TBD See Note 35 6. TBD See Note 23 6. TBD See Note 28 6. TBD See Note 35 6. Minimum Legs @ Optimal Legs @ Maximum legs @ 60 CFM/Leg 50 CFM/Leg 40 CFM/Leg TBD See Note 23 6. Minimum Legs @ Optimal Legs @ Maximum legs @ 50 CFM/Leg 40 CFM/Leg 60 CFM/Leg 23 Minimum Legs @ Optimal Legs @ Maximum legs @ 50 CFM/Leg 40 CFM/Leg 60 CFM/Leg TBD See Note 23 6. Minimum Legs @ Optimal Legs @ Maximum legs @ 60 CFM/Leg 50 CFM/Leg 40 CFM/Leg Number of 3" Diameter Branch Legs applicable to High Velocity Systems Only. Used only if methods other than Table 3 is used to determine duct sizes. 6. Number of 3” diameter legs specified in table above is for rating point only (i.e. at External Static Pressure of 0.5 in. wc. and speed TAP3, TAP1, TAP2 , TAP2 for AHB45, AHB60, AHB75, AHB90 respectively). Final leg count is to be determined by the installing contractor and is to be based on the following formula: NUMBER OF LEGS = TOTAL AVAILABLE CFM (AT THE SPECIFIC ESP) / DESIRED CFM per LEG (40, 50, or 60 CFM) Example: Given the design point for AHB045 of 0.8 ESP, Low fan speed (Tap5). From table 5.0, available CFM is 569 and the desired CFM per leg is 50 CFM. Therefore, Number of Legs = 569/50 = 11.38 rounded down to 11. 66.3 58.1 48.0 42.7 68.7 60.2 49.7 44.2 77.0 68.4 60.6 51.2 43.4 AIRFLOW (CFM) 82.0 72.8 64.5 54.4 46.2 1222 1174 1140 1100 1063 1014 91.6 81.3 72.0 60.8 51.6 1391 1350 1320 1281 1245 1209 1170 1131 1090 1064 1031 89.5 80.0 70.2 59.6 51.3 1561 1524 1490 1456 1428 1396 1364 1330 1230 1265 1224 89.8 80.2 69.1 60.0 50.3 1700 1666 1635 1604 1576 1543 1518 1492 1465 1430 1402 0 External Static Pressure (ESP) TABLE 5.4: AIR DELIVERY AND PERFORMANCE DATA (BOTTOM OR SIDE RETURN w/ FACTORY SUPPLIED FILTER) NOTES: 1. EWT - Entering Water Temperature (F). 2. CFM - Airflow in (Cubic Feet per Minute). 3. Legs - 3 inch diameter flexible ducts to diffusers. 4. 1 MBH = 1000 BTU/H. 5. Shaded box represents rating point; refer to wiring diagram for factory set speed taps. 37AHB07514KA5 + REU-KA3237FFUD(WD)-US 36