Download Burnham ES2 Specifications
Transcript
APPENDIX I – IQ Control System (continued) IQ Outdoor Reset Option Card Kit: P/N 102723-01 Installing the IQ Outdoor Reset Option Card is the simplest way to maximize the efficiency of any ES2 Boiler. The IQ Outdoor Reset Card is a microprocessorbased control that regulates the water temperature of the heating system based on the outdoor temperature. By modulating the water temperature of the heating system, the ES2 Boiler equipped with an IQ Outdoor Reset Option Card will deliver annual fuel savings up to 16%, while increasing home comfort. The IQ Outdoor Reset Option Card is simple to set up yet it includes a powerful list of features that can be customized for any job. Intelligent Hydronic Control Operating Setpoint is normally set to the High Limit Setpoint. However, when an IQ Outdoor Reset Option Card is installed the Operating Setpoint may be reduced to the outdoor reset or Domestic Hot Water (DHW) Setpoint. When an IQ Outdoor Reset Option Card is added the following user defined setpoints are available: • High Limit Setpoint - The High Limit becomes the upper limit for the operating setpoint. The operating setpoint can not be set higher than this value. The High Limit is set to protect the boiler and hydronic system from excessive temperature. • DHW Setpoint - The Operating Setpoint is set to the DHW Setpoint when the Control or Outdoor Reset Option Card DHW input is energized. This setpoint is set equal to the Indirect Water Heater manufacturer's recommended water temperature. • High Boiler Water Temperature - The High Boiler Water Temperature (also known as the "Boiler Water Design Temperature") setpoint is set to the lowest boiler water temperature that will heat the home on the home's design day. This adjustment typically depends on the type and quantity radiation (heating element) installed in the home. Kit Includes: •IQ Outdoor Reset Option Card •Outdoor temperature sensor w/mounting bracket & 60” lead •Instructions Major Features: •Selectable DHWP •Selectable/adjustable DHWP protection •Selectable/adjustable boost feature •Simple adjustment of reset curve IQ LWCO Option Card (Auto Reset) Kit: P/N 102711-01 IQ LWCO Option Card (Manual Reset) Kit: P/N 102714-01 IQ LWCO Option Cards add a low water cut-off function to ES2 Boilers. LWCO Option Cards plug into the IQ Option Panel and connect to the system-mounted sensor with a single-wire connection. IQ LWCO Option Cards feature built-in diagnostics, probe signal strength display, and include a “Test” and “Reset” feature in compliance with UL 353 and CSA 22.2 for CSD-1 Compliance in US and Canada. Kit Includes: •IQ LWCO Option Card •3/4” NPT level sensor •36” wire sensor connector •Instructions 50 Major Features: •UL 353 approved •Displays signal strength •Warns when probe cleaning required