Download Daikin EBHQ011AA6W1 Technical data

Transcript
• Monobloc • EDLQ011-016AA6V3
7
Wiring diagram
7-2
External connection diagram
EDLQ011-016AA6V3
Electrical connection diagram Altherma
For more details please check unit wiring
diagram
Standard parts
Outdoor unit
Power supply
Optional power supply
5 or 3 core
unit power supply: 400V or 230V + earth
Power supply (alarm indication, cooling/heating on/off
indication, solar interlock)
X1M: L1-L2-L3-N-Earth
or L-N-Earth
Backup heater power supply (3/6/9kW): 400V or 230V + earth
Bottom plate heater
option
Optional power supply
X1M:1-2-3-Earth
230V
3 core
3 or4 core
Optional parts
Only for EKRP1HB & EKSOLHWAV1
230V
X1M:1-2-3-Earth
A4P: Y1
Alarm output
A4P: Y2
Cooling/Heating
on/off output
2 way valve
Power supply
booster heater
A4P: Y3
Solar input
2 core
2x0.75
X7M
X5M
F28
230V
Only for EKHWSU*V3
X6M
5 core
G5 x 2.5
NO valve: X2M: 6-7
NC valve: X2M: 5-7
X4M:1-2-Earth
Alarm indication
230V
X2M: 17-18
Room thermostat
230V
1 core
solar interlock
2 core
230V
2 core
230V
A3P
230V
Note: min. distance to power cable * 5cm
2 core
X9A: (PCB A1P)
Possibility 2
Signal
3 core for C/H application
2 core for H only application
230V
Solar pump
Possibility 3
230V
5 core for C/H application
4 core for H only application
X2M: 1-2-3-4
230V
Only for EKSOLHWAV1
3 way valve
M3S (when EKHWE is intalled) selection
domestic hot water-floorheating
User interface
230V
Only for EKRTETS
2 core (3m
included)
Only for EKTR (wireless room
thermostat)
A4P: X1M: H-C-COM
X2M: L-N
R2T External sensor
(floor or ambient)
A3P: X1M:1-3
Signal
2 core
2 x 0.75
3 core
SPST:
X2M: 8-9-10
Optional parts
Only for EKRTW (wired room thermostat)
A3P: X1M: C-COM-H
X2M: 1-2-3-4
X2M: 19-20
X8M
M2S (E(B/D)(H/L)* Units)
for cooling mode
benefit kWh rate power supply
contact
Only for field supplied room thermostat
X2M: 1-2-3-4
2 core
Q*L
Clixon
2 way valve
4 core
X2M: 13-14
R5T - Thermistor
water temperature
Cooling/Heating
on/off indication
230V
Possibility 1
230V or 400V
Q2L - Clixon
booster heater
1 core
1 core
X3M: L1-L2-Earth
or L-N-Earth
Q*L
Clixon
7
1 core
A4P: YC
X1M: L1-L2-L3-N-Earth
or L-N-Earth
Domestic hot water tank
3
2 core
Booster heater power supply (3kW): 400V or 230V + earth
Field supply
Only for EKBPHT
X2M: 16-160
User interface
communication
3TW58016-2A
• AlthermaTM • Monobloc
133