Download Daikin EBHQ011AA6W1 Technical data
Transcript
• Monobloc • EDLQ011-016AA6V3 7 Wiring diagram 7-2 External connection diagram EDLQ011-016AA6V3 Electrical connection diagram Altherma For more details please check unit wiring diagram Standard parts Outdoor unit Power supply Optional power supply 5 or 3 core unit power supply: 400V or 230V + earth Power supply (alarm indication, cooling/heating on/off indication, solar interlock) X1M: L1-L2-L3-N-Earth or L-N-Earth Backup heater power supply (3/6/9kW): 400V or 230V + earth Bottom plate heater option Optional power supply X1M:1-2-3-Earth 230V 3 core 3 or4 core Optional parts Only for EKRP1HB & EKSOLHWAV1 230V X1M:1-2-3-Earth A4P: Y1 Alarm output A4P: Y2 Cooling/Heating on/off output 2 way valve Power supply booster heater A4P: Y3 Solar input 2 core 2x0.75 X7M X5M F28 230V Only for EKHWSU*V3 X6M 5 core G5 x 2.5 NO valve: X2M: 6-7 NC valve: X2M: 5-7 X4M:1-2-Earth Alarm indication 230V X2M: 17-18 Room thermostat 230V 1 core solar interlock 2 core 230V 2 core 230V A3P 230V Note: min. distance to power cable * 5cm 2 core X9A: (PCB A1P) Possibility 2 Signal 3 core for C/H application 2 core for H only application 230V Solar pump Possibility 3 230V 5 core for C/H application 4 core for H only application X2M: 1-2-3-4 230V Only for EKSOLHWAV1 3 way valve M3S (when EKHWE is intalled) selection domestic hot water-floorheating User interface 230V Only for EKRTETS 2 core (3m included) Only for EKTR (wireless room thermostat) A4P: X1M: H-C-COM X2M: L-N R2T External sensor (floor or ambient) A3P: X1M:1-3 Signal 2 core 2 x 0.75 3 core SPST: X2M: 8-9-10 Optional parts Only for EKRTW (wired room thermostat) A3P: X1M: C-COM-H X2M: 1-2-3-4 X2M: 19-20 X8M M2S (E(B/D)(H/L)* Units) for cooling mode benefit kWh rate power supply contact Only for field supplied room thermostat X2M: 1-2-3-4 2 core Q*L Clixon 2 way valve 4 core X2M: 13-14 R5T - Thermistor water temperature Cooling/Heating on/off indication 230V Possibility 1 230V or 400V Q2L - Clixon booster heater 1 core 1 core X3M: L1-L2-Earth or L-N-Earth Q*L Clixon 7 1 core A4P: YC X1M: L1-L2-L3-N-Earth or L-N-Earth Domestic hot water tank 3 2 core Booster heater power supply (3kW): 400V or 230V + earth Field supply Only for EKBPHT X2M: 16-160 User interface communication 3TW58016-2A • AlthermaTM • Monobloc 133