Download Simrad SD570 Installation manual
Transcript
Simrad SD570 / Base version 8.3 Receiving voltage response (VR) In order to measure the receiving voltage response, use the test hydrophone in the same position as for the source level measurements. Use the following menu settings: RANGE......: 3500 M GAIN.......: 50 MODE.......: BOW UP PULSEFORM..: CW-NORM TX POWER...: PINGSECTOR.: FREQUENCY..: TVG........: AGC........: RCG........: PP-FILTER..: OFF OMNI 27 KHZ OFF OFF OFF OFF COLOURTHRES: DISPLAYGAIN: 0 9 Enter the TEST menu and locate the line with the text: ECHO LEVEL. Check that the bearing and tilt angle are the same as for the source level measurements (see table 2), and read the ECHO LEVEL, which without a signal oscillator connected, is the noise level for the selected bearing. Enter the readout value into NOISE LEVEL in table 4. Connect a signal oscillator to the hydrophone, adjust the frequency to 27.0 Hz, and connect an oscilloscope to measure the output voltage to the hydrophone. Adjust the oscillator voltage until the ECHO LEVEL readout is 0.0 dB. Enter the measured hydrophone voltage U(p- p) into table 4 and calculate the U Hydr voltage as shown in the same table. 42 851--160117 / B