33 Trigger Commands
:TRIGger:AND:ENABle
Command
:TRIGger:AND:ENABle {{ON | 1} | {OFF | 0}}
The :TRIGger:AND:ENABle command enables the ability to further qualify
the trigger using other channels.
Query
:TRIGger:AND:ENABle?
The query returns the current state of the AND qualifier.
Returned Format
906
[:TRIGger:AND:ENABle] {1 | 0}<NL>