Download Crest Electronics CDVS-7000 User manual
Transcript
User Manual 9.8.1 Option –704: MIL-STD-704 rev D & E Tests. (Firmware) 9.8.1.1 General The MIL704 option is capable of performing most sections of MIL-STD-704 rev D and E in either of the AC or DC mode. Note: The Distortion Spectrum tests: Table I and II, Figure 7 Table III, Figure 12 Table IV, Figure 18 are not supported by the –704 option. These tests require the use of additional external equipment. 9.8.1.2 Initial Setup Nominal parameters for the AC Power source are as follows: Output Voltage 115V L-N Output Frequency 400 Hz Nominal parameters for the DC Power source are as follows: Output Voltage 28V or 270V L-N A setting outside these nominal values will disable the test and will prevent access to its Menu screens. 9.8.1.3 Revision The MIL704 option defaults to Revision E. The System is capable of performing Revision D test by changing the selection to Revision D. All Revision D tests can be performed except for the 270V DC TRANSIENT and ABNORMAL where Revision E level are used despite the revision selection. All levels and timing in this document refers to Revision E. For Revision D refer to MILSTD-704D date 9/30/1980 9.8.1.4 Tests Performed 9.8.1.4.1 STEADY STATE AC Mode: 1. Steady State Voltage and Frequency test 2. Waveform Distortion test 3. Voltage Modulation test 4. Voltage Unbalance test 5. Phase Unbalance test 6. Frequency Modulation test 240 i Series / iX Series