Download Venmar HEPA 4000 Specifications
Transcript
Appendix C: Water Source Heat Pump (WSHP) Water Line Piping Requirements and Options Water Supply and Return Piping Requirements • IMPORTANT WSHP external water supply and return piping shall be in accordance with National and Local Codes. Line sizing, pressure limiting devices, backflow preventers, strainers, valves, flow temperature and pressure measuring, freeze protection, all other safety or control piping requirements for system operation are the sole responsibility of the Installing Contractor and/or Design Engineer. The water supply must be sized for the minimum flow as indicated on the mechanical drawings. Recommended and required WSHP water line piping components with a detailed functional description are outlined below: • • • • • • • Manual shut-off valves in supply and return water lines are recommended for isolation and service. Pressure and temperature gauge connections in the supply and return water lines are recommended for testing and service. A water strainer (16–20 mesh minimum) in the supply water line is recommended on open loop systems to eliminate contaminants. Air vents are required on the high side of the water supply or inlet line to discharge the non-condensable air in order to avoid unexpected high head pressure and poor cooling/heating performance. Manual air vents are factory installed on the water condenser and economizer coil (if equipped). A balancing valve with pressure and temperature gauge connections in the return water lines is recommended for balancing and service. A two-way motorized on/off water shut-off valve is recommended to isolate water flowing through both the economizer coil (if equipped) and water-torefrigerant condenser for conservation when the unit is off. The motorized water valve must open 90 seconds prior to compressor start-up and remain open five seconds after the compressor is shut off. A waterside economizer coil, a three-way modulating water economizer valve and a temperature sensor on the water inlet or supply line and downstream of the economizer coil is required for energy conservation. The water temperature sensor is input to the DDC Control System which determines when to divert water to the economizer coil for energy conservation in cooling mode. The three-way motorized economizer valve and the inlet water temperature sensor are included with the WSHP WiSE coil option and factory provided and installed in the compressor compartment. VCES-VHC72-IOM-1H • • • A three-way modulating head pressure control valve is required to maintain stable operation of the refrigeration systems when operated on ground loop water systems when the design inlet water temperature is below 65°F [18°C] in the cooling mode. A refrigerant pressure transducer on the compressor discharge is used to modulate the water flow to the condenser using a 2 to 10 VDC signal to prevent the compressor discharge pressure from falling below the compressor operating limit. The three-way motorized valve and the pressure sensor option is factory provided and installed in the compressor compartment if the design inlet water temperature is below 65°F [18°C] in the cooling mode. A flow switch is required on the water return or leaving side of the condenser to monitor the presence or absence of flow which will shut down the compressor and unit if no flow is present. The water flow switch option is factory provided and installed in the compressor compartment. A water temperature sensor is required on the water return or leaving side of the condenser to monitor the water temperature which will shut down the compressor and unit for freeze protection if the leaving water temperature drops below 35°F [2°C]. The water temperature sensor option is factory provided and installed in the compressor compartment on 100% water systems. A relief valve must be installed in the water supply or inlet line if the maximum pressure of components is less than the water supply pressure to prevent damage, injury or death due to instantaneous release of high pressure water. ! WARNING Prior to connection of water supply or inlet line, verify water pressure is less than the maximum pressure for components in the water line. To prevent injury or death due to instantaneous release of high pressure water, relief valves must be installed in system water supply or inlet piping. Factory Installed Piping Options and Physical Description Some of the recommended and required components in the water supply and return line are available or included as factory installed and pre-wired options. When the factory installed options are selected the piping schematic, component size and Cv rating will be included based on compressor selected with the submittals. These components are mounted inside the compressor compartment, piped in copper lines with sweat or threaded connections as indicated in the submittals. Physical description, opera24