Display Modes The result of a measurement is displayed in the weight display mode or tolerance limit display mode. You can toggle between the two display modes by pressing w. – Weight Display Mode The weighed values are always shown on the main display, even if the corresponding results are over or under the tolerance limits. – – – – In the bar graph, the symbols for lower limit, target value and upper limit are displayed. The corresponding LED lights up: Yellow: Weighing result > upper tolerance limit Green: Weighing result lies within the tolerance limit Red: Weighing result < lower tolerance limit If no LED lights up: – the application is not yet completely initialized, or – weighing result lies outside of the check range, or – weighing platform has not reached stability – Tolerance Limit Display Mode The same as the weight display mode, but: – LL appears on the main indicator when the weighing result is less than the lower tolerance limit – HH appears on the main indicator for weighing result is greater than the upper tolerance limit – – – – – Digital I/O Interface The digital I/O interface is supported by the Checkweighing application. Four data output ports relay the following information (see diagram): Lighter Equal Heavier Set The “Set” output normally changes its voltage level when the load is near the target weight. Alternatively, the “Ready-for-Use” function (4.3.2) can be assigned to this output. In the application program, you can define whether these control ports are deactivated (4.4.1) always activated (4.4.2) activated at stability (4.4.3) activated within the check range (4.4.4) activated at stability within the check range (4.4.5) For example, this enables you to show the weighed or measuring result on a simple external indicator, similar to the 3 LEDs on the Combics 2. All data output ports have a high voltage level when: – The application has not been initialized – The weighing platform is not at stability and the menu setting “at stability ...” (4.4.3 and 4.4.5) was selected – The load is not within the checkweighing range (4.4.4) Checking Range 30 % Target weight 170% Lower limit Upper limit Lighter Equal Heavier Set Ready to operate Digital I/O Interface Control line “SET”: set and control lines: always/always at stability Checking Range 30 % Target weight 170% Lower limit Upper limit Lighter Equal – Bar Graph The bar shows a logarithmic display of the current load if the weight is anywhere from 0 to the minimum load, and a linear display for weights beyond that range. Heavier Set Ready to operate Digital I/O Interface Control line “SET”: set and control lines: within the check range/within the check range at stability 54