12-7 Programming and reprogramming
PROGRAM SEARCH BANKS
You may wish to specify your own frequency limits or
modes for program search banks. There are 20 program
search banks in total 00, 01, 02, 03, 04, 05, 06, 07, 08,
09, 10, 11, 12, 13, 14, 15, 16, 17, 18 & 19.
To accept the bank location of “05” and initiate the
programming process press
Example of reprogramming a search bank - “05”
Input the lower frequency limit: The legend “LO” will
flash on the right of the LCD inviting entry of the LOWER
frequency limit.
Let’s assume that you wish to reprogram the data contents
of search bank “5”: 433.000 to 433.6000 MHz, mode to
NFM, 15kHz I.F. bandwidth, 25 kHz tuning steps,
step-adjust off and comment to 70CM.
Note: The attenuator and aerial selection is made while
program search is in operation and is not programmed
into the stored data, this greatly increases the versatility
when in live use !
To make things easier for this example, first delete the
existing data.
Press
operation.
to place the receiver in a known state of
Press
then press the
key for more than one
second to access the DELETE menu. Press the
key three times to access the “DEL SRCH” menu (or
you could press the
key twice to get to the same
place).
Rotate the SUB DIAL until “BANK 05” is displayed on the
right of the LCD.
If data is already programmed into this bank the legend “*
*” will be displayed, if no data is present the legend “- -”
will be displayed.
Assuming that data is present, press the
key
to delete the contents, after about one or two seconds
delay the legend will change to “- -” to confirm deletion.
LO <<<
HI
MODE FM (set to AUTO if AUTOMODE is used)
IFBW 0.5 (skipped if AUTOMODE is used)
STEP 1.000 (skipped if AUTOMODE is used)
TXT
In this example key in
strokes are echoed onto the LCD.
, the key
Note: If a mistake was made keying in previous data,
you may move backward (or forward) through the
or
data input selection process by holding the
key for more than one second depending upon
which way you wish to move.
Input the upper frequency limit: The legend “HI” will
now flash on the right of the LCD confirming entry of the
previous data and inviting entry of the UPPER frequency
limit.
LO
HI <<<
MODE FM (set to AUTO if AUTOMODE is used)
IFBW 0.5 (skipped if AUTOMODE is used)
STEP 1.000 (skipped if AUTOMODE is used)
TXT
In this example key in
Press
mode.
to complete the sequence and return to VFO
To start programming select the data input menu by
pressing
Select the required bank by rotating the SUB DIAL, until
“BANK 05” is displayed on the right of the LCD (for this
example). As no data exists the legend “- - - - - - - - - -” will
be displayed, if data was present the upper (“HI”) and
lower (“LO”) frequency limits would alternatively be
displayed to warn that data was about to be over-written.
Select the receive mode: The legend “MODE” will
flash on the display (along with the legend “SR” on the
right of the LCD) inviting the receive mode to be
entered. The current receive mode is displayed to the
right of the “MODE” legend. For example, if the
receiver is currently in AUTOMODE the legend “MODE
AUTO” will be displayed. Rotate the SUB DIAL to select
the receive mode, the choice is: AUTO, FM, AM, LSB,
key acts as a short cut
USB & CW. Note: the
to AUTOMODE.