Download AR5000 Operating Manual
Transcript
12-7 Programming and reprogramming PROGRAM SEARCH BANKS You may wish to specify your own frequency limits or modes for program search banks. There are 20 program search banks in total 00, 01, 02, 03, 04, 05, 06, 07, 08, 09, 10, 11, 12, 13, 14, 15, 16, 17, 18 & 19. To accept the bank location of “05” and initiate the programming process press Example of reprogramming a search bank - “05” Input the lower frequency limit: The legend “LO” will flash on the right of the LCD inviting entry of the LOWER frequency limit. Let’s assume that you wish to reprogram the data contents of search bank “5”: 433.000 to 433.6000 MHz, mode to NFM, 15kHz I.F. bandwidth, 25 kHz tuning steps, step-adjust off and comment to 70CM. Note: The attenuator and aerial selection is made while program search is in operation and is not programmed into the stored data, this greatly increases the versatility when in live use ! To make things easier for this example, first delete the existing data. Press operation. to place the receiver in a known state of Press then press the key for more than one second to access the DELETE menu. Press the key three times to access the “DEL SRCH” menu (or you could press the key twice to get to the same place). Rotate the SUB DIAL until “BANK 05” is displayed on the right of the LCD. If data is already programmed into this bank the legend “* *” will be displayed, if no data is present the legend “- -” will be displayed. Assuming that data is present, press the key to delete the contents, after about one or two seconds delay the legend will change to “- -” to confirm deletion. LO <<< HI MODE FM (set to AUTO if AUTOMODE is used) IFBW 0.5 (skipped if AUTOMODE is used) STEP 1.000 (skipped if AUTOMODE is used) TXT In this example key in strokes are echoed onto the LCD. , the key Note: If a mistake was made keying in previous data, you may move backward (or forward) through the or data input selection process by holding the key for more than one second depending upon which way you wish to move. Input the upper frequency limit: The legend “HI” will now flash on the right of the LCD confirming entry of the previous data and inviting entry of the UPPER frequency limit. LO HI <<< MODE FM (set to AUTO if AUTOMODE is used) IFBW 0.5 (skipped if AUTOMODE is used) STEP 1.000 (skipped if AUTOMODE is used) TXT In this example key in Press mode. to complete the sequence and return to VFO To start programming select the data input menu by pressing Select the required bank by rotating the SUB DIAL, until “BANK 05” is displayed on the right of the LCD (for this example). As no data exists the legend “- - - - - - - - - -” will be displayed, if data was present the upper (“HI”) and lower (“LO”) frequency limits would alternatively be displayed to warn that data was about to be over-written. Select the receive mode: The legend “MODE” will flash on the display (along with the legend “SR” on the right of the LCD) inviting the receive mode to be entered. The current receive mode is displayed to the right of the “MODE” legend. For example, if the receiver is currently in AUTOMODE the legend “MODE AUTO” will be displayed. Rotate the SUB DIAL to select the receive mode, the choice is: AUTO, FM, AM, LSB, key acts as a short cut USB & CW. Note: the to AUTOMODE. AR5000 OPERATING MANUAL PAGE 51