Section 5 – Displaying and Using the Tuning Screens
5.3 Profit Optimizer’s DQP MV Optimizer Tuning
Table 5-3
Profit Optimizer’s DQP MV Optimizer Tuning Functions
Use the Profit Optimizer’s DQP MV Optimizer Tuning Screen for These Tasks . . .
Operator
Engineer
There are no Operator tasks from this display
(default).
•
Setting the 1st and 2nd order coefficients that define the economic
objectives for the process.
•
Setting the desired MV resting value
Field Descriptions
Table 5-4
Fields and Using the Targets
Profit Optimizer’s DQP MV Optimizer Tuning – Understanding the
Profit Optimizer’s DQP MV Optimizer Tuning – Field Descriptions and User Notes
Description
Field
Field Type
APL
Read-Only
CV #
Read-Only
User Notes
Default Access
No Access
The Profit Controller (RMPCT) application number
No Access
The CV number within the Profit Controller
(RMPCT) Application.
MV Description
Target
OPER
Select the target to call the MV Detail screen.
Description that characterizes the variable's
function or location.
Linear Obj
Coef
Target
Quadratic Obj
Coef
Target
Desired MV
Value
Target
∆ Soft Lo Limit
Read-Only
∆ Soft Hi Limit
Read-Only
1/00
ENG
Linear objective coefficient.
Positive values drives MV to low limit
Negative values drive MV to high limit
ENG
Quadratic objective coefficient.
ENG
Desired resting value for the MV during quadratic
optimization.
No Access
Offset from the control low limit that defines a low
limit for optimization.
No Access
Offset from the control high limit that defines a high
limit for optimization.
These values are used down in the Profit Controller
and are shown here for information only.
These values are used down in the Profit Controller
and are shown here for information only.