LECTOR®620
5.8.5.1.8
Teach-in code length
If the Teach-in code length parameter is activated, the code length of the matchcode is
taught in.
This reduces the likelihood of the code being confused with other codes.
5.8.5.2
Match-code Teach-in 2 (Additional)
The Match-code Teach-in 2 (Additional) group contains the parameters for teaching in
matchcode 2.
To activate a taught-in matchcode, the corresponding condition is selected e.g. for the
Conditions for Good Read parameter.
5.8.5.2.1
Activate teach-in mode
Depending on the settings for the Start teach-in parameter, the Activate teach-in mode parameter is used to define the signal for preparing or starting the teach-in process for the
match code.
The signal can, for example, originate from a key switch at one of the digital inputs or be
triggered via a command.
• NOT DEFINED: Match code is not taught in.
• SENSOR 1: The match-code teach-in process is prepared and started via a signal at digital
input 1 (e.g. a key switch).
• SENSOR 2: The match-code teach-in process is prepared and started via a signal at digital
input 2.
• EXT. INPUT 1 (see note): The match-code teach-in process is prepared and started via a signal at digital external input 1.
• EXT. INPUT 2 (see note): The match-code teach-in process is prepared and started via a signal at digital external input 2.
• SOPAS COMMAND: The match-code read-in process is prepared and started via a corresponding command.
The number of available digital inputs can be expanded via the CDB620/CDM420 connection module in conjunction with the CMC600 parameter memory module. The purpose
of the CMC parameter memory module is to act as an input expansion module and convert
a digital signal into a command. External digital outputs generally respond more slowly than
the internal digital inputs of the LECTOR®620.
82
© SICK AG · Germany · All rights reserved · Subject to change without notice
8013778/Y269/2013-11-27