Chapter 5
Parameters
ONLINE HELP SOPAS
LECTOR®620
5.10.13 Digital outputs/Beeper
The Digital outputs/Beeper tab contains all of the parameters for configuring the digital outputs.
These parameters define which events cause an output signal to be sent.
The required output signal function must be configured accordingly in another area. The
use of output signals as object triggers, for example, is set on the Application counters tab.
5.10.13.1 Output / Result 1
The Output / Result 1 group contains the parameters for modifying digital output 1.
5.10.13.1.1
Active
The Active parameter is used to select the event for which the digital output is activated.
• SOPAS COMMAND: The output is activated by a command. As a result, the defined statuses
can be displayed via a connected control lamp as a result of a controller (PLC) command.
• DEVICE READY: The output is activated as soon as the LECTOR®620 is operational.
• GOOD READ: The output is activated in the event of a successful reading.
• NO READ: The output is activated in the event of an unsuccessful reading.
• TEACH-IN 1 OK: The output is activated if the MATCHCODE TEACH-IN 1 was taught in successfully.
• TEACH-IN 1 NOK: The output is activated if the MATCHCODE TEACH-IN 1 was not taught in successfully.
• TEACH-IN 2 OK: The output is activated if the MATCHCODE TEACH-IN 2 was taught in successfully.
• TEACH-IN 2 NOK: The output is activated if the MATCHCODE TEACH-IN 2 was not taught in successfully.
• CONDITION MATCH 1: The output is activated if the read code corresponds to the matchcode
from CONDITION MATCH 1.
• CONDITION MULTCODES1: The output is activated if the number of read codes corresponds
to the required number from CONDITION MULTCODES1.
• CONDITION TEACHIN1: The output is activated if the read code corresponds to the matchcode from CONDITION TEACHIN1.
• CONDITION TEACHIN2: The output is activated if the read code corresponds to the matchcode from CONDITION TEACHIN2.
5.10.13.1.2
Function (Off)
The Function (Off) parameter is used to select the event for which the digital output is deactivated.
• TIMER/TRACKING: The output is deactivated after a certain period of time (Length).
• NEXT OBJECT TRIGGER: The output is deactivated as soon as the next reading gate is opened.
• SOPAS COMMAND: The output is deactivated by a command. As a result, the defined statuses can be displayed via a connected control lamp as a result of a controller (PLC) command.