Download Electro Industries Shark 200T Specifications
Transcript
B: Modbus Map and Retrieving Logs Modbus Address Hex Decimal Description (Note 1) Format Range (Note 6) Units or Resolution 7D21 - 7D21 32034 - 32034 Input Accumulators Scaling UINT16 bit-mapped -------- 22221111 7D22 - 7D22 32035 - 32035 Relay Accumulators Scaling UINT16 bit-mapped -------- 22221111 7D23 - 7D23 33036 - 33036 Fast pulse input selector UINT16 bit-mapped p------- -----nnn 7D24 - 7D3E 32037 - 32063 Reserved Comments # Reg 4 bits per input or output accumulator The nibble informs what should be the scaling of the accumulator 0=no-scaling, 1=0.1, 2=0.01, 3= 1m, 4=0.1m, 5=0.01m, 6=1u, 7=0.1u; the value 15 disable the accumulator. Example: suppose that the internal input accumulator #1 is 12345, and its corresponding scaling setting is “0011” (3 decimal). Then, the accumulator will be read as: Scaling 3, means 1m or 0.001. Scaled accumulator = 12345 * 0.001 = 12 (Twelve). When value 'nnn' is non-zero, it determines which of the card inputs will be a fast pulse detection input. The polarity bit 'P' tells the event to be detected: 1=opento-close; 0=close-to-open. There is no “any-change” detection mode. Set to 0. 7D00 - 7D00 32001 - 32001 Input#1 - 4 bindings & logging enables UINT16 bit-mapped First Overlay 44443333 22221111 7D01 - 7D01 32002 - 32002 Source for Pulse Ouput#1 UINT16 enumeration -----ppp ----vvvv 7D02 - 7D02 32003 - 32003 Kt [Wh/pulse] factor for Pulse Output#1 UINT16 bit-mapped ddVVVVVV VVVVVVVV 7D03 - 7D04 32004 - 32005 Output#2 Assignment and Kt 7D05 - 7D06 32006 - 32007 Output#3 Assignment and Kt Electro Industries/GaugeTech The Leader In Power Monitoring and Smart Grid Solutions 1 27 Block Size: Settings Registers for Digital I/O Pulse Output Card 1 1 63 write only in PS update mode One nibble for each input. Assuming "abcc" as the bits in each nibble: "a": select this input for EOI (End Of Interval)pulse sensing. "b": log this input when pulse is detected "cc": Input event trigger mode - Contact sensing method; 00 = none; 01 = open to close; 10 = close to open; 11 = any change. Every input has an associated internal accumulator (See input Accumulator Scaling), which is incremented every time the input changes according with the trigger mode crieteria “cc” 1 " ppp" (Phase) : 000 = none, 001 = Phase A, 010 = Phase B, 011 = Phase C, 100 = All Phases, 101 = Pulse from EOI(End Of Interval). "vvvv"(Value) : 0000= none, 0001 = Wh, 0010 = +Wh, 0011 = -Wh, 0100= Varh, 0101 = +Varh, 0110 = -Varh, 0111 = VAh, 1000= Received Wh, 1001= Delivered Wh, 1010= Inductive Varh, 1011 = Capacitive Varh 1 1 UINT16 "V…V" = not scaled energy value per pulse, from 0 to 9999. "dd"= decimal point position: 00=0.XXXX, 01=X.XXX, 10=XX.XX, 11= X.XXX. same as Output #1 UINT16 same as Output #1 2 Doc# E149701 2 MM-28