Download Agilent Technologies ESG Specifications
Transcript
ESG Family Signal Generators Option 200 Using Functions 3GPP W-CDMA Base Station Performance Testing Example Test Procedure Follow this example procedure to perform a 3GPP W-CDMA intermodulation response rejection test on your BS. Perform the subsections in this procedure sequentially, in the order they appear in this document. Subsection 1. Equipment Setup and Preliminary BER Verification Complete the following steps to connect the equipment and perform a BER verification test on your BS. Figure 2-20 Intermodulation Response Rejection Equipment Setup 1. Connect the BS to the test system as shown in Figure 2-20. a. Using the appropriate cables, adapters, and antennae, connect the outputs of the two ESGs and one RF signal generator to the RF input ports of the signal combiner. b. Connect the RF output port of the signal combiner to the RF input of the BS. c. Connect the system controller and the BER test platform to the BS. Fully Coded 3GPP W-CDMA Personality User’s and Programming Guide 2-109