Detailed descriptions 16.1 Motherboard All ports are designed as high current USB (500 mA), you can only use a maximum of 2 simultaneously as high current, however. CAUTION No USB devices can be connected which feed back voltage to the Box PC. PROFIBUS/MPI interface X4 PROFIBUS/MPI interface 1 Pinno. Short description Meaning Input / Output 1 – Unassigned – 2 – Unassigned – 3 LTG_B Signal line B of MPI module Input/output 4 RTS_AS RTSAS, control signal for received data stream. The signal is "1" when the directly connected AS is sending. Input 5 M5EXT M5EXT return line (GND) of 5 V supply. The current load of an external consumer connected between P5EXT and M5EXT may not exceed the 90 mA. Output 6 P5 EXT P5EXT power supply (+5 V) of the 5 V power supply. The current load of an external consumer connected between P5EXT and M5EXT may not exceed the 90 mA. Output 7 – Unassigned – 8 LTG_A Signal line A of the MPI module Input/output 9 RTS_PG RTS output signal of the MPI module. The control signal is "1" when the programming device is sending. Output Shield 1 134 on connector casing Optional product variant SIMATIC IPC627C Operating Instructions, 11/2010, A5E02669068-02