Download Moog 300A Specifications

Transcript
T200 User's Manual
4.6.5
SECTION 4: MOTOR GUIDE
Runout
The reduced runout provided by MOOG motors allows the attachment of various gear heads. The precision
manufacturing of the motor avoids loads caused by misalignments between motor and gear heads.
Diameter of the Shaft
Extension
øU [mm]
to 10
over 10 to 18
over 18 to 30
over 30 to 50
L=AH
see Table 4.6
Maximum Runout
Tolerance Class R
[mm]
0.015
0.018
0.021
0.025
Table 4.7 Shaft Runout
Pilot Diameter of
Mounting Flange
øAK [mm]
to 22
over 22 to <40
40 to 100
over 100 to 230
over 230 to 450
for øAK values)
Maximum Concentricity and
Perpendicularity
Tolerance Class R [mm]
0.025
0.03
0.04
0.05
0.063
Table 4.8 Flange Concentricity/Perpendicularity
PAGE 4-20