Download Panel Mount, Digital Motor Controller

Transcript
16
SECTION ONE - GENERAL INFORMATION
For safety reasons the T150-901 Power Supply and T164 Series Drives and the panel
on which they are mounted must be installed in enclosures or cabinets which provide a
degree of ingress protection against liquids and objects of at least IP54. These
enclosures or cabinets must be accessible to technically qualified service or
maintenance persons only. (Refer to Section 1.2.1 of this Users Manual).
For Electrostatic Discharge ( ESD ) reasons all service or maintenance persons must
ground themselves to the chassis of the equipment when performing service functions
inside the IP54 rated enclosure or cabinet in which the T150-901 Power Supply and
T164 Series Drives are installed. This may be done by using an ESD wristband with
earth strap.
All external d.c.. supply voltages used with the T150-901 Power Supply and T164
Series Drives must be supplied from power supplies which are compliant with the
requirements the EU EMC Directive.
All external computers, hand held terminals or similar equipment attached by the user
to the T150-901 Power Supply and T164 Series Drives must be CE marked as
compliant with the requirements of the EU EMC Directive.
An a.c. power input line filter is required to be installed by the user in the a.c. power
input supply lines to the T150-901 Power Supply. Details of a.c. power line filters which
have been tested with the typical configurations of T150-901 Power Supply and T164
Series Drives referred to in Section 1.3.2 of this Users Manual and are given in Section
2.3 of this Users Manual. Detailed installation instructions for such a.c. power line filters
are given in Section 2.3 of this Users Manual.
Ferrite EMC suppression components are required to be installed by the user on
cables connected to certain ports on the T150-901 Power Supply and T164 Series
Drives. Details of ferrite EMC suppression components which have been tested with
the typical configurations of T150-901 Power Supply and T164 Series Drives are
referred to in Section 1.3.2 of this Users Manual and are given in Section 2.5 of this
Users Manual. Detailed installation instructions for such ferrite EMC conformity
components are given in Section 2.5of this Users Manual.
Shielded cable is required to be installed by the user for many external user cable
connections to the T150-901 Power Supply and T164 Series Drives. Details of areas
where shielded cable must be installed and details of earthing arrangements
which must be implemented for the shields of such cables are given in Section 2.5 and
Section 2.9of this Users Manual. Installation requirements for external Regen
(Regenerative Circuit) resistors are given in Sections 2.5and 2.7of this Users Manual.
MOOG
T164 SERIES USER’S MANUAL