Transcript
16 SECTION ONE - GENERAL INFORMATION For safety reasons the T150-901 Power Supply and T164 Series Drives and the panel on which they are mounted must be installed in enclosures or cabinets which provide a degree of ingress protection against liquids and objects of at least IP54. These enclosures or cabinets must be accessible to technically qualified service or maintenance persons only. (Refer to Section 1.2.1 of this Users Manual). For Electrostatic Discharge ( ESD ) reasons all service or maintenance persons must ground themselves to the chassis of the equipment when performing service functions inside the IP54 rated enclosure or cabinet in which the T150-901 Power Supply and T164 Series Drives are installed. This may be done by using an ESD wristband with earth strap. All external d.c.. supply voltages used with the T150-901 Power Supply and T164 Series Drives must be supplied from power supplies which are compliant with the requirements the EU EMC Directive. All external computers, hand held terminals or similar equipment attached by the user to the T150-901 Power Supply and T164 Series Drives must be CE marked as compliant with the requirements of the EU EMC Directive. An a.c. power input line filter is required to be installed by the user in the a.c. power input supply lines to the T150-901 Power Supply. Details of a.c. power line filters which have been tested with the typical configurations of T150-901 Power Supply and T164 Series Drives referred to in Section 1.3.2 of this Users Manual and are given in Section 2.3 of this Users Manual. Detailed installation instructions for such a.c. power line filters are given in Section 2.3 of this Users Manual. Ferrite EMC suppression components are required to be installed by the user on cables connected to certain ports on the T150-901 Power Supply and T164 Series Drives. Details of ferrite EMC suppression components which have been tested with the typical configurations of T150-901 Power Supply and T164 Series Drives are referred to in Section 1.3.2 of this Users Manual and are given in Section 2.5 of this Users Manual. Detailed installation instructions for such ferrite EMC conformity components are given in Section 2.5of this Users Manual. Shielded cable is required to be installed by the user for many external user cable connections to the T150-901 Power Supply and T164 Series Drives. Details of areas where shielded cable must be installed and details of earthing arrangements which must be implemented for the shields of such cables are given in Section 2.5 and Section 2.9of this Users Manual. Installation requirements for external Regen (Regenerative Circuit) resistors are given in Sections 2.5and 2.7of this Users Manual. MOOG T164 SERIES USER’S MANUAL