Option 2. Control Wiring Solution using a Low Voltage Dry Contact from a Utility-Supplied Device • • This method requires low voltage to be passed across a Utility-supplied contact. Used by Nova Scotia Power, the dry contact is part of their Time-Of-Day meter. The transformer is only needed to provide low voltage to the dry contact. Examples of components: • Marcus 12/240 to 12/24 AC transformer - MRCMO50A. • Schneider relay - TLPRPM21B7 and Schneider relay base - TLPRPZF2. • Use a “normally open” contact if the Utility signal is an open contact for Off-Peak periods. (Shown) This is the standard in Nova Scotia and requires the NSPi meter lead wire #113397 to connect to the NSPi meter dry contact. • Use a “normally closed” contact if the Utility signal is a closed contact for Off-Peak periods. (Not Shown) • The suggested transformer and relay panel dimensions are 8” w x 8” h x 4” d. 7211270100 Rev03 8