Download Rheem Single Element Specifications
Transcript
The new design cylinder element barrels do not have an earthing tab and require the earth bond to be connected to the earthing tab on the thermostat clamp (refer to fig. 4). When installing an early or new type element on a cylinder barrel that has an earth tab, this earth tab must be used (refer to fig.3). When installing an early or new type element on a new type cylinder barrel that does not have an earth tab, the earth tab on the thermostat clamp must be used (refer to 4). Fig.3. Cylinder barrel Earth tab Fig.4. Thermostat clamp Earth tab Refer also to Technical Bulletins TB05 019 and TB05 020 Thermostat changes From August 14 2007, the Robertshaw EWT series thermostats have been replaced by the Robertshaw ST series thermostats. This change applies to all electric water heaters. It should be noted that although ST series thermostat is a direct replacement for the EWT series thermostat, the terminal connections and wiring arrangement is different. Therefore; Whenever an EWT series thermostat is replaced with a ST series thermostat as a spare part, each water heater will require rewiring at the thermostat. Refer to wiring diagrams in this service instruction for wiring arrangements utilising the new ST series thermostat. ST12 Replaces EWT1 TM013 Vulcan Electric Service Instructions REV: D D.O.I.: 05/09 This document is stored and maintained electronically by ST22 Replaces EWT2 10 Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”