Download Rheem Single Element Specifications

Transcript
Water Too Hot
Water too hot diagnostic
Does the temperature at the
hot tap correspond with or
near the thermostat setting?
Is a tempering valve
installed?
YES
NO
Explain to customer the reasons for
storing water hotter than they may desire
i.e.
1. When mixed with cold water more hot
water delivery is possible.
2. Prohibit bacteria growth.
Tempering devices should be suggested
as a solution.
NO
Tempering valve faulty.
Clean filters or replace.
YES
Is the thermostat in good
contact with the cylinder?
NO
Remove the thermostat and clean
any scale from the cylinder wall.
Re-tension bracket and refit
thermostat.
NO
Reset the ECO
YES
Are the thermostat ECO
contacts closed?
ECO TEST 1
ECO TEST 2
Are the thermostat contacts
closed?
THERMOSTAT TEST 1
THERMOSTAT TEST 2
YES
YES
Replace thermostat
NO
Is the element installed in the
correct orientation?
NO
Refit element correctly
YES
TM013 Vulcan Electric Service Instructions REV: D
D.O.I.: 05/09
This document is stored and maintained electronically by
Replace thermostat
21
Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”