Download Cooper Security 9751 User guide
Transcript
2. Programming Commands KEYSWITCH DISARM KEYSWITCH ARM FULL Event DOWNLOAD SUCCESS EXPANDER MISSING EXPANDER MISSING RESTORE FORBI MISSING FORBI MISSING RESTORE JAMMING PASSWORD DEFAULTS LOADED PROG MODE START PROG MODE END TD (Time and day) RESET TX BATTERY TROUBLE USER CODE CHANGED USER CODE DELETED OS CS 409 409 SIA Code RS TA TR TA TR XQ RH LB LS JT XT JV JX CID Code 412 137 137‡ 137 137‡ 380 627 628 625 384 - Notes: 1. If Command 143, option 1 is selected, all messages with a CID Code are sent. If option 0 is selected, the restores marked with ‡ are not sent. 2. The control unit logs an Anti-Mask event to the zone number one below that assigned the Anti-Mask type. See page 8 for an explanation of the Anti-Mask zone type. 132: Send Tampers as Burglary Some Alarm Receiving Centres (ARCs) experience problems if a control unit sends "restore" messages using SIA, wrongly interpreting them as "user restores". When using SIA reporting, Command 132 enables you to program the control unit to send tampers as alarms. Option 0 The control unit sends all SIA messages as specified in Command 131 (default). 1 For full alarm response, the control unit sends tampers as burglary (BA) and sends Contact ID 130 in place of Contact ID 137. Notes: 1. Compliance with PD 6662 / prEN 50131-1: 2004 (see page 85) at Grade 3 requires that Command 132 is set to 1. 2. If Command 132 is set to 0, Command 37 must also be set to 0. 3. Fast Format and plug-by outputs send tampers as alarms only if no tampers are allocated using Commands 151-158, 191-198, 211-218. As the default settings do not include tamper allocations, the normal operation of these outputs is to send tampers as alarms. 497096, issue 3 Page 53