Download Utica UBSSC-050 Operating instructions
Transcript
11 - GENERAL MAINTENANCE AND CLEANING 11.1 Beginning of Each Heating Season ! DANGER • Check boiler area is free from combustible materials, gasoline, and other flammable vapors and liquids. Before servicing, turn off electrical power to boiler at service switch. Close manual gas valve to turn gas supply OFF to boiler. Failure to comply will result in death or serious injury. • Visually inspect combustion air and vent piping for proper operation. Check for and remove any obstruction to flow of combustion air or vent gases. Immediately repair or replace pipe showing deterioration or leakage. Reassemble per instructions in section 6. Verify proper reassembly and resealing of system. ! CAUTION Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. • Visually inspect condensate drain line for proper operation. Checking for deteriorated or plugged condensate drain line. Verify condensate trap drains freely. NOTICE • Test safety relief valve for proper operation. Refer to valve manufacturer's instructions packaged with relief valve. Verify proper operation after servicing. NOTICE • Inspect burner and heat exchanger and clean (if necessary) by following instructions in “Annual Inspection and Cleaning of Boiler Components” in this section. Perform regular service and maintenance by qualified service agency at least once every 12 months to assure safe, trouble free operation and maximum efficiency. • Circulator pump and combustion air blower motor furnished with boiler are permanently lubricated from factory and require no further lubrication. Lubricate field sourced pumps and/or motors according to pump and/or motor manufacturer’s instruction. 11-1 Sight Glass • Check following components are operating properly and are free of blockages or obstructions: • air vent; • check venturi air inlet for blockage and clean as required; • verify pressure test port cap and combustion test port are in place; • return temperature sensor clip must be securely seated on pipe; Check boiler for any sign of leaks. • Check low water cutoff using user interface. Sight Glass • Check operation by pressing test button on low water cutoff. • "Low Water" LED should illuminate and burner should shut down. • Should get error message on User Interface (E36). • Every 5 years remove low water cutoff. Reinstall after cleaning. • Every 10 years replace low water cutoff. • Check flame signal with user interface. Should be 8 micro amps at 100%. Pressure Test Port • Visual inspection of flame through sight glass. Burner should be fully illuminated. See figure 9-5. • Check expansion tank. 35