 Example: One-step
Set the initial speed of rotation of the motor
START POWER 1 = 30%.
Set the time to reach maximum power (MAX POWER)
START TIME 1 = 5 seconds.
In this example set START TIME 2 = 0 seconds. - doing this will
specify that the motor start is a single step.
Set MAX POWER to 100%.
This Example shows that the motor is started with 30% power, and
within five seconds linearly increases power to 100%.