Download All Weather Inc AWOS 3000 Specifications
Transcript
Does the Present Weather sensor send status codes to the DCP display? Are Thunderstorm/ Lightning data bad? 44 Replace the wires running between the DCP and the Thunderstorm/Lightning sensor Contact AWI Customer Service +1 (916)928-1000 Test and repair the continuity of the reference wire and the power line and ground connections for the DCP, Present Weather controller, and Present Weather sensor Remove the Present Weather "reference" wire from the Present Weather interface card TB1-6 (red). Measure the AC voltage between the end of the wire and TB2-7. Reconnect the wire. Was the voltage less than 2 V AC? Contact AWI Customer Service +1 (916)928-1000 Remove the Thunderstorm/Lightning sensor "reference" wire from DCP Thunderstorm/ Lightning sensor interface card TB1-6 (red). Measure the AC voltage between the end of the wire and TB2-7. Reconnect the wire. Was the voltage less than 2 V AC? Contact AWI Customer Service +1 (916)928-1000 Replace the Thunderstorm/ Lightning sensor (P/N 6500) Replace the wires running between the DCP and the Present Weather controller Remove the Thunderstorm/Lightning sensor wires from DCP TB4-1 (white) and TB4-2 (black). Measure the voltage on the wires. Reconnect the wires. Was the voltage the exact same as measured in the previous step? Contact AWI Customer Service +1 (916)928-1000 Remove the wires from the DCP Thunderstorm/Lightning interface card TB1-4 (white) and TB1-5 (black). Measure the DC voltage between TB1-4(+) and TB1-5(-). Reconnect the wires. Was the voltage 0.2–1 V? Replace the Present Weather controller and associated sensor (P/N 6490 & M404806) Contact AWI Customer Service +1 (916)928-1000 Remove the Present Weather sesnsor wires from DCP TB4-1 (white) and TB4-2 (black). Measure the voltage on the wires. Reconnect the wires. Was the voltage exactly the same as measured in the previous step (0.2–1 V)? Review the status codes per the 6490 User’s Manual "AWOS Maintenance and Troubleshooting" section, and adjust or repair as needed Remove the wires from the Present Weather interface card TB1-4 (white) and TB1-5 (black). Measure the DC voltage between TB1-4(+) and TB15(-). Reconnect the wires. Was the voltage 0.2–1 V? Are Present Weather data bad? Replace the Thunderstorm/ Lightning sensor (P/N 6500) Contact AWI Customer Service +1 (916)928-1000 Replace the Present Weather controller and associated sensor (P/N 6490 & M404806) Contact AWI Customer Service +1 (916)928-1000 Contact AWI Customer Service +1 (916)928-1000 T R O U B L E S H O O T I N G G U I D E AWOS 3000 MAINTENANCE 5.7 Present Weather and Thunderstorm/Lightning Sensors