1. Introduction
The SCX Solar cylinder is a high quality stainless steel unvented cylinder designed for use with all
solar systems to provide hot water from a cold mains water supply of between 3bar and 12bar.
Reduced performance is available at lower pressures but the units are not suitable for pressures
lower than 1.5bar and flow rate of less than 20 litres per minute. The indirect heat exchange surfaces
are designed to provide a rapid heat up time. The unit comes complete with all the necessary safety
equipment to comply with legislation governing the installation of such systems.
1.1
Cylinder Suitability:
The SCX Solar cylinder should only be used as part of a solar installation and configured as shown in
figure 1.2. Additional safety devices may be required if the cylinder is operated with other heat sources.
2. Technical Specifications
Model Number
Storage capacity (litres)
Cylinder diameter (mm)
Aux Water volume (l)
Overall height (mm)
T&P Valve (mm)
Lower Immersion (mm)
Top Immersion (mm)
Solar Flow (mm)
Solar Return (mm)
Cold Inlet (mm)
solar Coil size sqm
Aux Coil size sqm
Auxiliary Flow (mm)
Auxiliary Return (mm)
Weight when full (kg)
Heat-up time* (m)
Re-heat time* (m)
Heat Loss in 24hr (kw)
Secondary Return
Primary flow/return connections (mm)
Cold feed/hot draw off connections (mm)
Maximum water supply pressure (bar)
System operating pressure (pre-set) (bar)
Expansion vessel charge pressure (bar)
Maximum primary working pressure (bar)
Package includes:
Expansion vessel ltr
Inlet Valve Group (pressure reducing valve, non
return valve, 6 bar expansion relief valve, line
T/P valve 7bar 90degC (factory fitted)
15mm to 22mm Tundish
22mm motorised valve
Control/limit thermostat box
Immersion heater
SCx175sd SCx215sd
SCx255sd
SCx305sd
SCx175si
SCx215si
SCx255si
SCx305si
175
574
90
1300
1080
593
908
542
380
300
1.1
219
20
14
1.78
•
22
22
12
3
3
3
215
574
130
1542
1322
593
1150
542
380
300
1.1
267
24
17
2.19
•
22
22
12
3
3
3
255
574
170
1809
1589
593
1417
542
380
300
1.1
314
28.5
20
2.31
•
22
22
12
3
3
3
305
574
215
2085
1865
593
1693
542
380
300
1.1
374
34
24
2.51
•
22
22
12
3
3
3
175
574
105
1300
1080
593
542
380
300
1.1
0.75
904
742
223
18
13
1.78
•
22
22
12
3
3
3
215
574
140
1542
1322
593
542
380
300
1.1
0.75
904
742
271
21.5
16
2.19
•
22
22
12
3
3
3
255
574
180
1809
1589
593
542
380
300
1.1
0.75
904
742
318
25
19
2.31
•
22
22
12
3
3
3
305
574
230
2085
1865
593
542
380
300
1.1
0.75
904
742
378
30
22
2.51
•
22
22
12
3
3
3
18
18
25
25
18
18
25
25
•
•
•
−
•
2
•
•
•
−
•
2
•
•
•
−
•
2
•
•
•
−
•
2
•
•
•
•
•
1
•
•
•
•
•
1
•
•
•
•
•
1
•
•
•
•
•
1
2.1 Heat-up & Reheat Times*
*Heat-up and reheat times are for a guide only and are based on a primary flow temperature of 60oC
and heating water from 15oC to 60oC. The immersion of the cylinder or external boiler must be used
to raise the temperature to 60oC from the maximum temperature achieved at any time by the solar
system,.
Reheat times are those to heat 70% of the cylinder from cold.
3