Download Dimplex SCx175si Specifications
Transcript
1. Introduction The SCX Solar cylinder is a high quality stainless steel unvented cylinder designed for use with all solar systems to provide hot water from a cold mains water supply of between 3bar and 12bar. Reduced performance is available at lower pressures but the units are not suitable for pressures lower than 1.5bar and flow rate of less than 20 litres per minute. The indirect heat exchange surfaces are designed to provide a rapid heat up time. The unit comes complete with all the necessary safety equipment to comply with legislation governing the installation of such systems. 1.1 Cylinder Suitability: The SCX Solar cylinder should only be used as part of a solar installation and configured as shown in figure 1.2. Additional safety devices may be required if the cylinder is operated with other heat sources. 2. Technical Specifications Model Number Storage capacity (litres) Cylinder diameter (mm) Aux Water volume (l) Overall height (mm) T&P Valve (mm) Lower Immersion (mm) Top Immersion (mm) Solar Flow (mm) Solar Return (mm) Cold Inlet (mm) solar Coil size sqm Aux Coil size sqm Auxiliary Flow (mm) Auxiliary Return (mm) Weight when full (kg) Heat-up time* (m) Re-heat time* (m) Heat Loss in 24hr (kw) Secondary Return Primary flow/return connections (mm) Cold feed/hot draw off connections (mm) Maximum water supply pressure (bar) System operating pressure (pre-set) (bar) Expansion vessel charge pressure (bar) Maximum primary working pressure (bar) Package includes: Expansion vessel ltr Inlet Valve Group (pressure reducing valve, non return valve, 6 bar expansion relief valve, line T/P valve 7bar 90degC (factory fitted) 15mm to 22mm Tundish 22mm motorised valve Control/limit thermostat box Immersion heater SCx175sd SCx215sd SCx255sd SCx305sd SCx175si SCx215si SCx255si SCx305si 175 574 90 1300 1080 593 908 542 380 300 1.1 219 20 14 1.78 • 22 22 12 3 3 3 215 574 130 1542 1322 593 1150 542 380 300 1.1 267 24 17 2.19 • 22 22 12 3 3 3 255 574 170 1809 1589 593 1417 542 380 300 1.1 314 28.5 20 2.31 • 22 22 12 3 3 3 305 574 215 2085 1865 593 1693 542 380 300 1.1 374 34 24 2.51 • 22 22 12 3 3 3 175 574 105 1300 1080 593 542 380 300 1.1 0.75 904 742 223 18 13 1.78 • 22 22 12 3 3 3 215 574 140 1542 1322 593 542 380 300 1.1 0.75 904 742 271 21.5 16 2.19 • 22 22 12 3 3 3 255 574 180 1809 1589 593 542 380 300 1.1 0.75 904 742 318 25 19 2.31 • 22 22 12 3 3 3 305 574 230 2085 1865 593 542 380 300 1.1 0.75 904 742 378 30 22 2.51 • 22 22 12 3 3 3 18 18 25 25 18 18 25 25 • • • − • 2 • • • − • 2 • • • − • 2 • • • − • 2 • • • • • 1 • • • • • 1 • • • • • 1 • • • • • 1 2.1 Heat-up & Reheat Times* *Heat-up and reheat times are for a guide only and are based on a primary flow temperature of 60oC and heating water from 15oC to 60oC. The immersion of the cylinder or external boiler must be used to raise the temperature to 60oC from the maximum temperature achieved at any time by the solar system,. Reheat times are those to heat 70% of the cylinder from cold. 3