Download Emerson C1300 User`s manual
Transcript
System Management: FRU LEDs Type: Byte: Data Field: (continued) Response Data 3 LED States Bits [7:3] reserved, set to 0 Bit [2] 1b if Lamp Test has been enabled Bit [1] 1b if override state has been enabled Bit [2] 1b if IPMC has a Local control state 4 Local Control LED Function 00h LED is off (default if Local Control not supported) 01h-FAh LED is blinking Off duration specified by this byte, on duration specified by byte 5 (in tens of milliseconds) FBh-FEh reserved FFh LED is on 5 On Duration LED on-time is measured in tens of milliseconds Lamp Test time in hundreds of milliseconds if byte 4=FBh, time value must be less than 128. Other values when Byte 4=FBh are reserved. Otherwise, this field is ignored and shall be set to 0h. 6 Local Control Color Bits [7:4] reserved, set to 0 Bits [3:0] 0h reserved 1h Blue 2h Red 3h Green 4h Amber 5h Orange 6h White 7h-Fh reserved 7 Override State LED Function—is required if either override state or Lamp Test is in effect. 00h LED override state is off 01h-FAh LED override state is blinking Off duration is specified by this byte, on duration specified by byte 8 (in tens of milliseconds) FBh-FEh reserved FFh LED override state is on 8 Override State On Duration—is required if either override state or Lamp Test is in effect (in tens of milliseconds). 10009109-01 ATCA-9305 User’s Manual 7-23