3) DOOR LOCK SWITCH 1) CLASS Failure Status "Tick" Sound "LE" Error Details Tick Sound happens "LE" with tick sound "LE" without tick sound DOOR not Power Failure/Forced Power Off during open operation Power on state PCB ERROR MODE When Door is locked/unlocked, this Solenoid Working Normal Sound sound is heard. check the joining status of Assemble Connector Connector slipped out "LE" connector by eye Close Door securely DOOR closed loosely "LE" Replace DOOR AS Failure of DOOR HOOK "LE" Tick sound happen CATCH CAM broken "LE" Replace DOOR S/W check the joining status of Connector slipped out "LE" Assemble Connector connector by eye Refer to below checking Terminal slipped out "LE" Insert Receptacle no.2 method. or no.3 Refer to below checking Solenoid Coil "LE" Replace DOOR S/W method. Disconnection During operation, "Power Failure" or "Forced Power S/W OFF" causes door not to be opened until maximum 5 minutes pass. Cause Water remained in tub Diagnosis of Failure Solution Check whether the water After draining water, level is over safety level. open the door Prevent the burn due to hot temp. after dry. - hot temp. in tub Follow below process ETC Checking Method of wiring/coil disconnection, connector slipping out on PCB board : Operate with the Door lock switch connected 1. Replacing method of DOOR LOCK SWITCH 1) Open DOOR, disassemble CLAMP SPRING for fixing gasket 2) Disassemble GASKET 3) Disassemble two screws for DOOR LOCK S/W 4) Disassemble DOOR LOCK S/W 5) Assemble in the reverse order 33