Download SGI Origin 3900 User`s guide
Transcript
L1 Controller Commands Table 3-2 l1dbg Commands (continued) Command Description l1dbg pppdump <on|off> Controls data dump on junkbus ppp errors. l1dbg promreq <on|off> Controls PROM request debugging. l1dbg qsusp <exp> <exp> Sets queue suspend time req/rsp and evt. Used on all bricks. leds Use the leds command to read the value of the group 0 and group 1 status LEDs. In systems that include a C-brick, this command is only valid for the C-brick. These LEDs connect to I/O expanders that monitor group 0 status LEDs 0 through 15 and group 1 status LEDs 0 through 15. In the output of the leds command, the CPUs correspond to the status LEDs as follows: • CPU A corresponds to I/O expander A_0100001x - group 0 status LEDs 0 through 7. • CPU B corresponds to I/O expander A_0100010x - group 0 status LEDs 8 through 15. • CPU C corresponds to I/O expander A_0100011x - group 1 status LEDs 0 through 7. • CPU D corresponds to I/O expander A_0100100x - group 1 status LEDs 8 through 15. The number next to the CPU letter is a hexadecimal value that represents the value of the status LEDs that connect to the I/O expander (a bit set to 1 indicates the LED is on, a bit set to 0 indicates the LED is off). Example 3-37 shows sample output from the leds command. For systems with C-bricks containing IP41 processors, the output of the leds command matches the numbering of the CPUs. Example 3-37 leds Command Output 001c07-L1>leds CPU A: 0x02 CPU B: 0x02 CPU C: 0x0f CPU D: 0x0f 007-3938-003 65