Download Cisco OL-12518-01 Specifications
Transcript
4.4 DS3000, DS4000 and DS5000 Storage Systems With DS3000, DS4000 or DS5000 arrays, the number of physical drives to put into an array always presents a compromise. On one hand striping across a larger number of drives can improve performance for transaction based workload and on the other it can have a negative effect on sequential workload. A common mistake made when selecting array width is the tendency to focus only on the capability of a single array to perform various workloads, however also at play in this decision is the aggregate throughput requirements of the entire storage server. Since only one controller of the DS3/4/5000 will be actively accessing a given array a large number of physical disks in an array can create a workload imbalance between the controllers. When selecting an array width, an additional consideration is its effect on rebuild time and availability. A larger number of disks in an array will increase the rebuild time for disk failures which can have a negative effect on performance. Additionally more disks in an array increases the probability of having a second drive fail within the same array prior to rebuild completion of an initial drive failure which is an inherent exposure to the RAID5 architecture. If RAID6 architecture is implemented, then the array can tolerate a second drive failure. The storage system will automatically create a logical drive for each host attached (logical drive id 31). This drive is used for in-band management, so if the DS Storage System will not be managed from that host, this logical drive can be deleted. This access drive does count towards the maximum of accessible volumes per host maximums, so this action will allow for one more logical drive to use per host. If a Linux or AIX based server is connected to a DS Storage System, the mapping of this access logical drive should be deleted. When storage resources are utilized by a SVC cluster, best practice guidelines suggest RAID arrays using either four or eight data drives plus parity drive(s) depending on the RAID level. Whenever DS3/4/5k storage systems are configured for data replication, the ports connecting the source and target storage systems should be dedicated for data mirroring only. No other traffic types, such as SVC or host connections, should be shared on the mirror ports. With direct attached hosts, considerations are often made to align device data partitions to physical drive boundaries within the storage controller. For the SVC this © IBM Copyright, 2012 www.ibm.com/support/techdocs Summary of Best Practices for Storage Area Networks Version: January 26, 2012 20