Download C106 Coded Access Keypad CS106 Door Entry & Coded Entry
Transcript
CS106 Combined Door Entry and Coded Access Troubleshooting CS106 Combined Door Entry and Coded Access Symptom Possible Cause/Remedy Ž Use the table below to determine the most probable cause of a fault condition. Speech Unit. Refer also to page 26 for problems with the coded access system (C106 Keypad). Ž Speech Unit is not tight against the panel grill. Telephone Problems Ž Symptom Volume adjustment required on the Possible Cause/Remedy Constant tone/feedback ‘O’ connection between Speech unit and telephone is open circuit. when in use. Ž Volume adjustment required on speech Ž unit. Ž close together. Speech unit is not tight against the Ž panel grill. Low Speech Volume Entrance panel and telephone are too The entrance panel is surrounded by reflecting walls. Ž Panel grill is blocked Ž Panel grill is blocked. Ž More than one telephone is off the Ž Wiring fault on the speech signal Ž hook. No speech when the phone Speech unit supply voltage is low. is buzzed Check 10V - 15V across ‘C’ and ‘H’. 39 connections ‘R’ or ‘T’: ‘R’ carries the phone microphone signal to the speech unit; ‘T’ carries the Speech unit microphone to the phone. 40