Download ADTRAN TSU 120 User manual
Transcript
Chapter 5. Configuration Menu Menu Item DATA Description Used to control the inverting of the DTE data. This inversion can be useful when operating with an HDLC protocol. Often used as a means to ensure 1s density. Choices: Normal, Invert If Invert is selected, zero (0) inhibit should also be selected to prevent an open DTE input from placing zeros on the network. CTS Used to control characteristics of CTS. Choices: Normal*, Force On *See Table 5-1 on page 5-20. DCD Data Carrier Detect. Indicates to the DTE when a valid signal is being received at the Network Interface. Choices: Normal*, Force On *See Table 5-1 on page 5-20. DSR Data Set Ready. This signal indicates to the DTE when the DCE is turned on and ready for operations. Choices: Normal*, Force On *See Table 5-1 on page 5-20. 0 INHIB The Nx interface will detect an uninterrupted string of zeros (0s) being transmitted toward the network. If 0s are transmitted for >1 second, the TSU 120 will force 1s. Choices: On, Off 61202129L1-1 TSU 120 User Manual 5-19