102 Interface Serial (Option on Both TTP 7020 and TTP 7030) Serial (Option on Both TTP 7020 and TTP 7030) The printer has a 10-pin connector on the control board. This connector can be used to connect to an external RS-232 adapter. See Connecting To The Computer on page 18 for installation instructions. The transfer speed of the serial interface can be set to between 2 400 and 115 200 bits/s. This low transfer speed limits the printing speed. Printing full-width graphics with 115 200 bits/s result in printing speeds of about 24 mm/s for the 80-mm version of the printer, and 16 mm/s for the 112-mm version. Applications where text-only printouts are to be printed are suitable for serial interface because of its easy to use bi-directional capability. Table 7 • Serial Connector Pin Assignment Printer 2 (RXD) 3 (TXD) 4 (DTR) 5 (GND) 6 (DSR) 7 (RTS) 8 (CTS) PC (9 pole D-sub) 3 (TXD) 2 (RXD) 6 (DSR) 5 (GND) 4 (DTR) 8 (CTS) 7 (RTS) Setup Options Baud 2 400, 4 800, 9 600, 19 200, 38 400, 57 600, 115 200 bits/s Flow control None, Xon / Xoff, or Hardware Data bits 7/8 Stop bits 1 (fixed) Parity None, Odd, or Even Default settings: 9600 bits/s, 8-bits, No parity, 1 stop bit, and hardware flow control. See also: Default Parameter Settings on page 74. P1003636-001 TTP 7020™/TTP 7030™ Technical Manual 02/11/2009