Connections As indicated in Table 6 on page 64, this run of wire can support 700mA. Total mA on this run of wire: (A) 25mA + (B) 30mA = 55mA<700mA = OK As indicated in Table 6 on page 64, this run of wire can support 454mA. Total mA on this run of wire: (D) 110mA + (E) 30mA + (F) 110mA + (G) 110mA = 360mA<454mA = OK As indicated in Table 6 on page 64, this run of wire can support 136mA. Total mA on this run of wire: (A) 25mA + (C) 30mA = 55mA<136mA = OK Digiplex -EVO- - 62 - Programming Guide