Download Security Command XR200-485 Programming instructions
Transcript
AREA INFORMATION 14.19 BANK/SAF NO YES Bank Safe & Vault (485B only) NO disables the Bank Safe & Vault feature for this area. When selected as YES, schedules set for this area and the time of day cannot be changed while the area is armed. Program schedules before arming: A Bank Safe & Vault area can only be disarmed during scheduled times. If you arm the area before programming a schedule, the panel must be reset before the area can be disarmed manually from a keypad or the Bank Safe & Vault option in Zone Programming turned to NO. Zones in areas programmed for Bank Safe & Vault cannot be bypassed or force armed. Do not assign Bank Safe & Vault area to an Arming zone. Arming zones can disarm Bank Safe & Vault areas outside of a schedule. 14.20 COMMON NO YES Common Area Select YES to enable this area to operate as a common area. This area is armed when the last area in the partition is armed and is disarmed when the first area in the partition is disarmed. You can have multiple common areas in each partition. For the common area to work properly, do not assign the common area to any user codes. A user code can be programmed to arm and disarm the common area from a keypad at any time, but the common area will not function as a common area. 14.21 TWO MAN NO YES Two Man Rule (485B only) Select YES to enable this area to require two user code entries to disarm or allow a door access. When a user presents a code to a keypad or reader requesting a door access or disarm, 2ND CODE displays and requires the entry of a different user code with at least the same authority. NO disables the Two Man Rule for this area. XR200-485 Programming Guide Digital Monitoring Products 33