Download Bosch Rextroth TSplus Technical data

Transcript
8981 500 278 7/09 TSplus Assembly Conveyors
Bosch Rexroth Corporation
Schematics
RELAY LOGIC SEQUENCE
02-01
1)
Start signal enables CR1 and rotation begins. LS1 is activated (open).
02-02
2)
After 10 degrees of rotation LS1 is de-activated (closed). CR2
and CR3 are enabled and CR1 is disabled, Rotation continues
02-03
3)
After 360 degrees of rotation LS1 is activated (open). CR2 and CR3
are disabled and rotation stops.
02-04
02-07
START
1280 JUMPER 3003
CR3
1281
12
PC-1
02-08
02-09
1282
DC COM
02-06
1280
+24VDC
02-05
PC
OUT
CR1
1280
8
PC-2
8
HOME
LIMIT SWITCH
12
1281
LS1-1
LS1-2
1320
14
12
CR1 1284 CR3
12
4
9
1285
1
LIFT AND ROTATE CONTROL +24 VDC START SIGNAL
Fig. 11
01-07, 01-08
02-09, 02-12
2.2 mfd 50V
3
1280
1282 BEGIN ROTATION
13
+ C1
02-11
02-12
CR1
14
NOTE: ROTATE START PULSE
ON TIME 250NS
SUPPLIED BY
CUSTOMER
CR3
02-10
1283
4
+
3
CR2
CR3
SSR1
1282
13
02-07, 02-1002-12
4
4
BEGIN
ROTATION
01-07, 01-08
02-19, 01-14
1282
01-04
17