Download USPS DP450C Technical information
Transcript
Enhanced Carbon Monoxide Fire & Heat Detector The MDU601EX detector combines the features of both the MU601EX detector and the MD601EX detector to provide a combined CO and Rate of Rise Heat Detector where the sensitivity of the CO detector is enhanced in response to a fast rate of change of temperature. Product Code 516.016.001.Y (Vol 01B-04-D14) MDU 601EX Enhanced Carbon Monoxide Fire & Heat Detector M300/500/MUBEX Detector Bases and Ancillaries Product Codes 517.025.002 M300Ex Mounting base 517.035.002 M500Ex Mounting base 517.025.010 M300/M500 Base lock kit 517.050.610 MUBEX Mounting Base 517.025.022 MB35 Flush mounting kit for M300/400/500 series 517.035.006 M500 Protective cover 517.001.231 DHM69 Deckhead mounting kit. This deckhead mounting is also suitable for 300/500 series detectors. 517.001.120 System 601 EOL Unit (Pk 10) Olsen T54B - Point Type Heat Detector Constructed from stainless steel, the T54B is an extremely rugged heat detector that can be used to detect fires in the harshest of environments. The T54B can be used in environments with ambient temperatures up to 200 oC and, being hermetically sealed, is impervious to most contaminants. The T54B is suitable for use in areas with explosive atmospheres. Certified as a flameproof (Ex d) device, it can be used in Zone 1 and Zone 2 hazardous areas when installed using flameproof mounting enclosures and conduit. Page 64 Classified as a simple device, the T54B can be used in Zone 0 areas when connected to a suitable intrinsically safe barrier. For reliable operation, it is recommended that T54B detectors have set points 20 oC or 20% (whichever is higher) above the maximum temperature they will be exposed to in normal operation. Preferred factory preset temperatures are: 60, 90, 100, 145 oC; normally with open contacts. Technical Specification Operating voltage @ 0.5A: 240Va.c. to 24Vd.c. Switching Current: 5 to 500mA Contact Resistance: <1 ohm Actuating Temp.:(factory set) 60 to 240 oC Fixed Temp. Only: *Type E Accuracy: + or - 5% Ambient Temp.: -40 to +270 oC Relative Humidity: 100% RH Protection Category: IP67 Thread Size: M20 x 1.5mm Product Codes 516.033.011 T4E60X T54B Point Type heat detector - 60 oC 516.033.012 T4E90X T54B Point Type heat detector - 90 oC 516.033.013 T4E100X T54B Point Type heat detector - 100 oC 516.033.014 T4E145X T54B Point Type heat detector - 145 oC Other temperatures and normally closed contacts are available by request. 514.001.017 IF500Ex Intrinsically safe addressable interface suitable for T54B probes Datasheet - Product Code PSF24 “System 601/602 for Hazardous Areas”