Download USPS DP450C Technical information
Transcript
Addressable Fire Systems - UL/FM Approved Analogue Addressable TFX-400 Series TFX400 The AUTOCALL TFX-400 is a self contained, small addressable panel in a single cabinet. The AUTOCALL TFX-400 includes 2 analogue, addressable signalling line circuits that provide 99 points each. The AUTOCALL TFX-400 uses proven technology, used in the TFX-500M and TFX-800M fire alarm and detection systems. The AUTOCALL TFX-400 is designed to be used with conventional or analogue, addressable fire detection devices, in any combination. As a stand alone panel, the AUTOCALL TFX-400 meets the needs of any small-to-mid size building or building complex; networking capability allows the TFX-400 to be used in larger buildings or building complexes. Features . 198 Analogue addressable points . Fully upgradable . Ideal for retrofit applications . System status information at a glance . One panel size with many features of larger TFX panels . Compact cabinet fits between wall studs . Cabinet space for up to 17 Amp hour battery . Semiflush or surface mount flexibility . Low cost Features - Options . Remote OCP and virtual front panel . Networking capability . Graphical user interface Listings & Approvals . UL Listed, File S2561 - Local - Local with Releasing Device Service - Auxiliary - Remote Station (Protected Premises Unit) Proprietary (Protected Premises Unit) - Central Station (Protected Premises Unit) - Fire Alarm Control Unit - Proprietary Receiving Unit - Central Station Receiving Unit . CSFM No. 7165-1493:147 7170-1493:167 Technical Specification Note: A U T O C A L L T F X-400 is intended for use within a building interior, free from exposure to moisture, condensation and excessive dust. Operating Temp.: 0 to +49oC Humidity: 85% Non-Condensing Loop Styles: NFPA 72 Style 4 & 6. Line isolators optional for short circuit isolation Max. Add Per Loop: 99 Max Loops per Sys: 2 Operating Voltage: 26Vd.c., 300mA Supervisory Current: 20mA per loop (plus load) 24mA per loop (plus load) Resistance: Max. 75Ohms Capacitance: Max. 0.5 microfarad (mutual) Inductance: Max. 1.5 millihenry (total) Product Codes 557.180.625 TFX400 Two loop UL/FM approved fire control panel. Supplied in grey with Thorn Security branding. 976422 TXF400 Two loop UL/FM approved fire control panel. Supplied in red with Grinnell branding. Analogue Addressable TFX-500/800 Series . . . 557.180.623 557.180.624 The AUTOCALL TFX-500M, TFX-800M, TFX-500MV and TFX-800MV comprise the AUTOCALL TFX family of self contained Fire Alarm Control Panels. CALL TFX-500M provides up to 198 analogue addressable initiating and output devices, while the AUTOCALL TFX-800M expands the capacity to 990 devices. The basic system hardware and software is common for both AUTOCALL TFX500M and TFX-800M, therefore the 500M can be expanded to 800M on site. AUTOCALL TFX controls are designed to be used with conventional or analogue addressable fire detection devices, in any combination thereof. Engineered with advanced microprocessor technology, these fire control panels provide a dynamic level of applications flexibility. The exclusive CONSYS software configuration tool for site specific user programming easily guides the trained installer through a menu prompted decision process. Features . Conventional and analogue addressable fire detection . 198 Analogue addressable initiating and output devices plus 1600 discrete inputs or outputs (TFX-500M) . 990 Analogue addressable initiating and output devices plus 1100 discrete inputs or outputs (TFX-800M) . TFX-500M may be expanded to TFX-800M on site . 80 Character LCD display; 40 user defined message characters . Power limited, all circuits . Integral LED zonal or group annunciator . Degrade mode in TFX-800M operates evacuation signals if CPU failure occurs before or during an alarm . Smoke detector condition monitoring with automatic environmental compensation . Individual smoke detector sensitivity selectable from the operator interface . Historical event log for view or print . Fully site programmable . Solo test and alarm verification per group or point . Automatic time control functions with holiday exceptions . Six access levels with unique 0911 Fire Department Access . Automatic and manual detector sensitivity adjustment Alarm resound by zone or device Modular, expandable Single, dual and multi-channel voice systems, 25 and 70 VRMS . Networking capability to the graphical user interface from any TFX panel. Listings & Approvals . UL 864 Listed for Local, Auxiliary, Remote Station and Proprietary Receiving Station Service; File S2561 . CSFM No. 7165-0062:161 . MEA No. 415-92-E . FM ID No. OX2A8.AY NOTE: AUTOCALL TFX-500M and TFX-800M are intended for use within a building interior, free from exposure to moisture, condensation and excessive dust. Technical Specification Temperature Range: 0oC to 49oC Relative Humidity: 85% Non Condensing Loop Styles: NFPA 72 Style 4 and 6. Line isolators optional for short circuit isolation Max. Add. Per Loop: 99 Max. Loops Per Sys: 2 (TFX-500M) 10 (TFX-800M Voltage: 26Vd.c., 300mA Supervisory Current: 20mA per loop (plus load) Alarm Current: 24mA per loop (plus load) Resistance: Max 75 Ohms Capacitance: Max. 0.5 microfarad (mutual) Inductance: Max. 1.5 millihenry (total) Max. Continuous Dis: 6500 feet Product Codes 557.180.623 TFX-500M 2 loop fire control panel with red architectural door. Grinnell branded in 3 tier housing with FCM/OCM and 16 LED indicator. Supplied complete with 4” shallow backbox. Other colours and branding available on request. 557.180.624 TFX-800M Fire detection panel with red architectural door and Grinnell branding in 7 tier housing with FCM/ODM and 80 LED indicator. Supplied prebuilt complete with 6” backbox. Other colours and branding available on request. Page 15