Download Compaq TL891 - DLT Tape Library User`s guide
Transcript
DLT MiniLibrary (TL891) - User’s Guide Example: To set the DLT1 Density would involve the following steps: 4.2 1. With the next to line 1, press the Enter button, moving the Notice the appears at the end of line 4. 2. Use the and buttons to scroll line 2 to display the possible settings. After making your selection, press the Enter button to save the new selection. You can return to the screen in Figure 4-5 by pressing the Escape button. The returns to line 1. 3. This time, if you press the button instead of the Enter button, the moves to line 3, allowing you to set DLT1 Compression. 4. Press the Escape button repeatedly until the submenu in Figure 4-4 reappears. 5. Repeat this procedure for each configuration option you want to change. to line 2. Descriptions of Configuration Options The items available on the Configuration Menu are as follows: 4.2.1 Set Data Format This option enables you to specify DLT data Density and DLT data Compression requirements. The default for both options is Auto Selection (this will not affect the default operation of the TZ89N Tape Drive). 4.2.2 Set SCSI This option enables you to 1) enable or disable the library robotics SCSI bus parity checking, and 2) set the SCSI addresses of the drives and the library robotics. The defaults are: parity on; DLT 0 address = 4; DLT 1 address = 5, robotics address = 0. 4–4 EK–TL891–UG. A01