FrameMaker Ver.5.5(PC) EP1054/EP1085/EP2030 TROUBLESHOOTING
98.05.15
(4) C0070: Toner Replenishing Motor's failure to turn
C0071: Toner Replenishing Motor turning at abnormal timing
Symbol
PC112
M8
PWB-A
Name
Toner Hopper Home Position Sensor
Toner Replenishing Motor
Master Board
1174C28TAA
Step
Check Item
Result
Action
1
Is C0071 being shown?
YES
Begin with step 3.
Does the Toner Bottle turn when two
or three copies are made with the
Original Cover raised?
YES
Perform step 3.
2
NO
Perform step 4.
YES
3
Make two or three copies with the
Original Cover raised. Does the voltage
across PJ17A-2B on PWB-A and GND
change to DC0V when the Toner Bottle
is stopped and to DC5V when the Bottle
is turned during the copy cycle?
YES
4
Make two or three copies with the Original Cover raised. Does the voltage
across PJ5A-6A on PWB-A and GND
change to DC0V when the Toner Bottle
is stopped and to DC24V when the Bottle is turned during the copy cycle?
Replace PWB-A.
Check the Bottle Holder or PC112.
NO
Replace M8.
Replace PWB-A.
NO